MHT258a (Engl.)
3-3
(c) Perpendicularity of mounting face of flange to shaft for flange-mounted motor
The indicator is fitted rigidly on the shaft extension.
[unit : mm]
(a)
(b)
(c)
Flange-mounted
Flange-mounted
Flange-mounted
0.02
0.06
0.08
(7)
Stress of Cable
Strain relief and mechanical protection for the connection cables and connector has to be provide in final installation.
3.2 Amplifier
(1) Installation environment
(a) Ambient climatic conditions
Ambient conditions
Amplifier
Motor
Temperature
−
20 to
+
80[
℃
]
−
10 to
+
70[
℃
]
Humidity
90[%] RH max.
In transportation and storage
(*1)
Air pressure
86 to 106 [kPa]
Temperature
−
10 to
+
55[
℃
]
−
10 to
+
40[
℃
]
Humidity
90[%] RH max.
Control rooms and equipment rooms
(*1)
Air pressure
86 to 106 [kPa]
Install location (*2)
For indoors
(*1) Free from condensation, no condensation, no formation of ice
(*2) Site-altitude should be 1000[m] and below.
(b) Avoid use under the following conditions.
(i) Location near oil, steam or corrosive gas
(ii) Location where strong electric or magnetic field exists
(iii) Accommodation in the same panel together with high voltage (2[kV] or higher) equipment
(iv) Sharing of the same power supply with the equipment which generates large noise.
(v) In vacuum
(vi) In explosive atmosphere
(vii) Under acceleration vibration
Summary of Contents for Faldic-a Series
Page 1: ...RYS V Type User s Manual MHT258a Engl...
Page 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Page 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Page 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Page 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...