(1) Basic specification
(a) 0.03 to 0.75 [kW] for 200 [V] input voltage of amplifier
Amplifier type
RYS
□□□
S3-VVS
300
500
101
201
401
751
Applicable motor output (*1)
[kW]
0.03
0.05
0.1
0.2
0.4
0.75
Phase, freq.
3-phase for power supply, single-phase for control, 50/60 [Hz]
Input
Voltage
200/200-220-230 [V], +10 to
−
15[%]
System
Sinusoidal PWM current control (all digital)
Carrier freq.
[kHz]
10
Feedback
16-bit serial encoder (one-revolution resolution 16-bit, multi-revolution 16-bit)
Loading
for 0 to 100 [%] deviation
Supply volt.
±
1 [r/min]
max.
For
−
10 to +10 [%] fluctuation
Speed
control
accuracy
Amb. temp.
±
15 [r/min] max. for
−
10 to +55 [°C] variation (at analog volt. input)
Speed range
1 : 5000 (at rated load)
Freq. response
500 [Hz] (at J
L
= J
M
(*2) )
Load inertia. max.
100 times of the motor rotor inertia, permissible
Control
data
Overload capability
300 [%] for 3 [sec], 450 [%] for 1.5 [sec]
Braking
Regenerating, dynamic with external braking resistor
Protection
OC (output overcurrent), OS (overspeed), L
V
(low voltage, undervoltage),
H
V
(high voltage, overvoltage), Et (encoder trouble), Ct (circuit trouble, amplifier trouble),
dE (data error, memory error), CE (combination error), rH
2
(resistor heat 2),
EC (encoder communication error), CtE (cont (control signal) error),
OL (motor overload), rH (resistor heat, braking (OB) resistor overheat),
OF (over flow, deviation excessive), AH (amp. heat, amplifier overheat),
EH (encoder heat, encoder overheat), AL (absolute data lost),
AF (absolute data over flow), SE (system error)
Function
Display, setting
CHARGE (red), 7-segment LED with 5-digit and 4 operation keys
Installation place
For indoors, 1000 [m] and below of site-altitude, under clean atmosphere,
no explosive hazardous gas and vapour is existing.
In the case of compliance with the European standard :
Pollution degree = 2, Over voltage category =
Ⅱ
Temp., humidity
−
10 to +55 [°C], 90 [%] RH max. (free from condensation)
Ambient
condition
Vibration / shock
4.9 [m/s
2
] / 19.6 [m/s
2
] acceleration, acceptable (max.)
Others
DC reactor terminals (P1, P+) for higher harmonics suppression.
UL/cUL (compliance with UL508), European standards (compliance with EN50178)
Mass (weight)
[kg]
0.9
1.2
1.5
(*1) Use amplifier and motor as a specified pair of types given in the table of 9.3 (3) (d).
If the RYS401 (0.4 [kW]) type amplifier and GYS201 (0.2 [kW]) motor (which is a step smaller than the optimum combination) is
combined as a pair, allowable breakdown (max.) torque of 0.2 [kW] motor can be obtained as 450% (in the case of the breakdown
torque of the motor itself is 450% and above) of the rated torque.
Furthermore, in this case, other data are as follows :
•
The moment of load inertia after conversion into motor shaft extension is at most 30 times the moment of inertia of motor rotor.
•
Acceleration/deceleration time up to rated speed is 2 [ms] or more.
•
The motor shaft extension is directly mechanically connected and is subjected to no external radial or thrust force.
(*2) Moment of inertia
J
L
: Moment of load inertia after conversion into motor shaft extension
J
M
: Moment of inertia of motor rotor
Summary of Contents for Faldic-a Series
Page 1: ...RYS V Type User s Manual MHT258a Engl...
Page 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Page 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Page 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Page 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...