MHT258a (Engl.)
5-6
5.2.2 Alarm reset [RST]
This signal input resets the alarm detection being issued from the amplifier.
At the ON edge of alarm reset [RST] signal of control input signals, the alarm detection is reset.
Alarm detection can also be reset in the trial operation mode [
] by keypad panel.
Alarm detection can also be reset by turning on power supply again.
■
Interface
■
Parameter setting
To allocate the alarm reset [RST] signal to the control input terminal, set (11) to the system para. If this signal is not allocated to the control
input terminal, this signal is deemed "always off."
■
Related item
How to reset alarm reset is as listed below:
1) At the ON edge of [RST] signal of control input signal
2) ENT key operation in the trial operation mode [
]
3) Press
∧
key and
∨
key simultaneously (longer than 1s) at alarm detection [
]
4) Press
∧
key and
∨
key simultaneously (longer than 1s) at alarm history [
]
5) Power shut down and turn on again
To initialize the history of alarm detection, press ENT key in the trial operation mode [
].
Alarm reset [RST] (11)
ON edge : Resets the alarm detection
(ON edge means at the transition from OFF level to ON level.)
P24
M24
2.2k
+24V