MHT258a (Engl.)
6-21
6.3.6 Always valid
Arbitrary signals among the control input signals can be always effective.
System parameter 87, 88
Para.
Name
Setting range
Initial value
Change
87
CONT always valid 1
0 to 56 (in increments of 1)
0
Power
88
CONT always valid 2
0 to 56 (in increments of 1)
0
Power
Function (Input signal) number to system para. 1 to 8
0: Not assigned
11: Alarm reset [RST]
38: Torque control
51: X1
1: Run command [RUN]
14: ACC0
43: Override valid
52: X2
2: Forward command [FWD]
16: Position preset
44: Override1
53: X3
3: Reverse command [REV]
27: Pulse train ratio 1
45: Override2
54: Free-run [BX]
5: Origin return [ORG]
28: Pulse train ratio 2
46: Override4
55: Edit permit command
6: Origin LS [LS]
29: P-action
47: Override8
56: Current position output
7: +OT
30: Torque limit
48: Interrupt input valid
8: -OT
34: External fault input
49: Interrupt input
10: Forced stop [EMG]
37: Position control
50: Deviation clear
The assignable signals are as follows:
1 : Run command [RUN]
The run command becomes always effective.
14 : ACC0
Only acceleration time 2 and deceleration time 2 become always effective.
27 : Pulse train ratio 1
28 : Pulse train ratio 2
Pulse train ratio 1 or 2 becomes always effective. Do not assign these two signals 1 and 2 at system
para. 87 and 88 at the same time.
29 : P-action
P-action is always effective. Assignment is not necessary.
30 : Torque limit
Torque limit value becomes always effective. Unless assigned, maximum torque limit value (basic
para. 59) setting is effective.
37 : Position control
38 : Torque control
Position control or torque control becomes always effective.
43 : Override valid
Override becomes always effective.
44 to 47 : Overeride 1, 2, 4, 8
Only specifically determined magnification becomes effective.
48 : Interrupt input valid
Interrupt input becomes always effective.
51 to 53 : [X1], [X2], [x3]
Only specifically determined multistep speed becomes effective.
Remarks: The signals that have been assigned to system para. 87 or 88 are always effective.
The only two signals can be “always effective.”
Summary of Contents for Faldic-a Series
Page 1: ...RYS V Type User s Manual MHT258a Engl...
Page 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Page 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Page 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Page 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...