MHT258a (Engl.)
1-5
1.3 Functions
The FALDIC-
α
series has 3 types of control function for particular applications.
(1) RYS-V type : Pulse train/speed control (velocity)
Maximum input frequency 500[kHz]
Rotates according to pulse train from host control equipment, or
speed command from encoder or variable resistor.
The host interface has :
・
DI/DO speed (minimum DI/DO),
・
SX bus,
・
Open network, etc.
(2) RYS-L type
:
:
:
:
Linear positioning function (linear motion)
Maximum command value
±
79,999,999
The amplifier incorporates a linear positioning function.
A linear positioning system can be used by ball-screw,
rack and pinion or other mechanical equipment systems.
It is usable for 99-point of positioning data, current
(present) position output, immediate positioning, M-code
output and other functions.
The host interface has
:
・
DI/DO position (expanded DI/DO),
・
SX bus,
・
Open network, etc.
(3) RYS-R type
:
:
:
:
Rotational indexing function (rotation)
Maximum indexing number 4095
The amplifier incorporates a rotational indexing function.
A rotational indexing system for ATC, tool magazine,
loader/unloader, etc. can be used.
The rotational indexing function is usable for shorted route
control, one-point halt, single-direction infinite rotation, etc.
The host interface has
:
・
DI/DO position (expanded DI/DO),
・
SX bus,
・
Open network, etc.
Summary of Contents for Faldic-a Series
Page 1: ...RYS V Type User s Manual MHT258a Engl...
Page 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Page 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Page 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Page 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...