10-6
MHT258a (Engl.)
10.5 AC reactor (reactor for impedance matching)
(1) AC reactor application
Provide and connect an AC reactor in any of the following cases.
(a) Power supply capacity is large
When the power supply capacity exceeds 500 [kVA] (*), the input current of the amplifier becomes large at the time of power on, and there is
a possibility where the rectifying diodes of the amplifier are damaged.
Note : (*) Cable length of 20 [m] with specified cable diameter size.
(b) Power supply voltage is unbalanced
Connect an AC reactor if the power supply voltage unbalance rate is 3 % or higher.
Unbalance rate of power supply voltage [%]
=
−
−
×
Max voltage V
Min voltage V
phase average voltage V
.
[ ]
.
[ ]
[ ]
3
100
(c) Suppression of higher harmonics
Higher harmonics current is generated because an amplifier is of capacitor input type.
AC reactor suppresses voltage distortion in the power supply system.
(2) Connection
Connect an AC reactor to the primary (power supply) side of the amplifier.
Input voltage class
[V] 100
200
Amplifier output
[kW] 0.05, 0.1
0.2
0.03 to 0.2 0.4
0.75
1, 1.5
2, 3
4, 5
VVS6
VVS
Amplifier type
RYS
□□□
S3-
500, 101
201
300 to 201 401
751
102, 152
202, 302
402, 502
AC reactor type
ACR2- 0.4A
0.75A
0.4A
0.75A
1.5A
2.2A
3.7A
5.5A
10.6 External braking resistor
: External dimension : Refer to 10.8 (3)
A braking resistor is provided (built-in) with the amplifier for 0.2[kW] over.
However, if load variation is wide, elevation (hoisting) load, or higher frequent operation, the following external braking resistor should be
added.
(1) Data of external braking resistor
Input voltage class
[V]
100
200
Amplifier output
[kW]
0.05, 0.1
0.2
0.03 to 0.2 0.4
0.75
1, 1.5
2, 3
4, 5
Amplifier type
RYS
□□□
S3-
VVS6
VVS
500, 101
201
300 to 201 401
751
102, 152
202, 302
402, 502
Resistor type
WSR-401
WSR-751 WSR-152 DB11-2
DB22-2
(**) [W] 17
17
25
75
115
130
Resistance
[
Ω
] 27
68
15
10
5.8
Built-in resistor
(**) [W]
12
12
20
30
60
[
Ω
]
Not
applicable
27
Not
applicable
68
33
18
9
5.5
Note : (**) Cont. : Continuous operation duty at 25[
℃
], allowable
(2) Data of NTC-thermistor embedded in the external braking resistor
Resistor type
WSR-
Open circuited the thermistor at
the following temperature [
℃
]
Withstand AC voltage tested
for one minute [kV]
Contact capacity
DC
401
135
±
5
1.5
30 [V], 3 [A]
751
2.5
152
150
±
10
Summary of Contents for Faldic-a Series
Page 1: ...RYS V Type User s Manual MHT258a Engl...
Page 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Page 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Page 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Page 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...