MHT258a (Engl.)
5-42
・
Origin return pattern 3 (pattern 3 in basic para. 71)
At the ON edge of [ORG] signal, the motor rotates by the origin return reversing quantity at the origin return speed. Then, the operation
from (a) through (e) is carried out.
If the [OT] signal toward the opposite to the origin return direction is detected during rotation by the origin return reversing quantity, the
movement stops once, and then carries out the
“
Origin return pattern 1
”
.
ON
Z-phase encoder
OFF
Origin return [ORG]
OFF
Origin LS [LS]
ON
OFF
Origin return end
ON
[PSET] (level)
ON
OFF
[PSET] (one shot)
Speed
Time
Summary of Contents for Faldic-a Series
Page 1: ...RYS V Type User s Manual MHT258a Engl...
Page 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Page 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Page 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Page 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...