MHT258a (Engl.)
5-54
5.7.9 Dynamic braking
This signal is output when the amplifier detects major fault.
This signal is turned on when such a major fault has occurred that the amplifier cannot drive the motor, and is retained until alarm reset
signal is input.
Dynamic braking is a braking type to short-circuit the coils between three phases of a synchronous motor to generate power.
Once the motor is stopped, braking force is not retained.
The output terminal of dynamic braking is +30V DC, 50mA. This cannot directly close a magnetic contactor. Use a general purpose relay or
FUJI SSC (solid state contactor).
■
Interface
■
Parameter setting
To allocate the dynamic braking signal to the control output terminal, set (15) to the system para.
■
Related items
・
Major fault
Fault that cannot drive motor
Dynamic braking (15)
ON : Major fault is detected
OFF : In normal operation
・
Minor fault
Protection against overheat etc.
+24V
Indication
Detection contents
Overload
Overspeed
Overvoltage
Encoder error
Encoder communication error
Control power error
Memory error
Undervoltage
Overcurrent
Combination error
Resistor heat 2
CONT signal error
System error
Indication
Detection contents
Resistor overheat
Deviation over
Amplifier overheat
Encoder overheat
ABS data lost
Multiple rotation overflow
Bus communication error
Summary of Contents for Faldic-a Series
Page 1: ...RYS V Type User s Manual MHT258a Engl...
Page 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Page 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Page 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Page 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...