10-4
MHT258a (Engl.)
10.2 Auto circuit breaker (FAB, MCCB), earth leakage circuit breaker (ELCB) and magnetic contactor (MC) : Recommended Fuji’s
type
FAB or ELCB is installed on the power supply side for turning power supply and promptly cutting off a fault current such as short-circuit current.
MC is used when amplifiers are disconnected from the power supply with an external signal or in the case of power ON/OFF from remote
operation panels.
The types are applicable to the power supply capacity is up to 500 [kVA], specified cable diameter size with the wiring length within 20 [m] is
used, and ON/OFF of the primary side of one amplifier is performed. Connect an AC reactor if the power supply capacity exceeds
500 [kVA].
(i) For 200[V] class input voltage of amplifier
Amplifier output
[kW] 0.03 to 0.2
0.4
0.75 to 1.5
2
3
4, 5
Amplifier type
RYS
□□□
S3-VVS 300 to 201
401
751 to 152
202
302
402, 502
FAB
type SA 33B/5
33B/10
33B/15
53B/30
53B/40
33B/50
For each
amplifier
current [A] 5
10
15
30
40
50
ELCB type
EG 33B/5
33B/10
33B/15
53B/30
53B/40
53B/50
Fuji’s
Recommended
type
MC type
SC- 5-1(19A)
5-1 (32A)
1N (50A)
2N (60A)
(ii) For 100[V] class input voltage of amplifier
Amplifier output
[kW] 0.05
0.1
0.2
Amplifier type
RYS
□□□
S3-VVS6 500
101
201
FAB
type SA 33B/3
33B/5
33B/10
For each
amplifier
current [A] 3
5
10
ELCB type
EG 33B/3
33B/5
33B/10
Fuji’s
Recommended
type
MC type
SC- 5-1(32A)
10.3 Surge suppressor (surge killer)
Shown below are recommended surge suppressors (for 250 [V] or less ) to be installed on peripheral devices (magnetic contactor, solenoid,
brake, etc. ) of amplifier.
DC equipment should be equipped with a diode for surge voltage suppression.
[unit : mm]
For magnetic contactor, etc.
For control relay, etc.
300
40±1
30±1
27.5
500[
Ω
] (1/2[W])+0.2[
μ
F]
Type : S2-A-O
200[
Ω
] (1/2[W])+0.1[
μ
F]
300
40±1
20±1
27.5
Type : S1-B-O
Protection circuit, example
AC circuit (C-R circuit)
DC circuit (diode)
Load
Load
Summary of Contents for Faldic-a Series
Page 1: ...RYS V Type User s Manual MHT258a Engl...
Page 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Page 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Page 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Page 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...