MHT258a (Engl.)
5-41
・
Origin return pattern 2 (pattern 2 in basic para. 71)
At the ON edge of [ORG] signal, the aforementioned operations (a) through (e) are carried out.
If the [+OT] or [-OT] signal in the origin return direction is detected in the course of origin return, the motor stops once. Then, the following
operations are carried out.
(f) The motor starts rotation at the origin return speed in the opposite to the origin return direction.
(g) The motor stops on detection of OFF to ON to OFF transition of the
“
Origin LS
”
[LS] signal.
(h) Operations (a) through (e) are carried out again.
In case the [OT] signal toward the opposite to the origin return direction is detected during (f) operation in the origin return operation, the
motor stops immediately ([LS] on is not detected).
In this case, origin return operation has not been completed.
Encoder Z-phase
OFF
ON
Origin return [ORG]
ON
OFF
Origin return end
ON
[PSET] (level)
ON
OFF
[PSET] (one shot)
Speed
Time
OFF
Origin LS [LS]
[+OT]
ON
Summary of Contents for Faldic-a Series
Page 1: ...RYS V Type User s Manual MHT258a Engl...
Page 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Page 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Page 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Page 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...