
MHT258a (Engl.)
5-40
・
Origin return pattern 1 (pattern 1 in basic para. 71)
At the ON edge of [ORG] signal, the aforementioned operations (a) through (e) are carried out.
If the [+OT] or [-OT] signal of the
“
Origin return direction
”
is detected during origin return operation, the motor stops immediately. In this
case, origin return is not completed. The
“
Origin return end
”
signal still remains off.
The origin return operation can be carried out again regardless of the on/off status of
“
Origin return end
”
signal.
OFF
ON
Encoder Z-phase
Origin return [ORG]
Origin LS [LS]
Origin return end
Positioning end [PSET]
(level)
Positioning end [PSET]
(one shot)
Speed
Time
OFF
OFF
OFF
ON
ON
ON
Summary of Contents for Faldic-a Series
Page 1: ...RYS V Type User s Manual MHT258a Engl...
Page 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Page 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Page 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Page 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...