MHT258a (Engl.)
8-4
8.2 Touch panel
After making sure of status when power is turned on, carry out a test running from the touch panel.
CAUTION
At the test running, the motor must not be connected to the mechanical equipment system, to be prevent unexpectedly
break the mechanical equipment system.
Before the test running, firmly tightened the mounting-flange so that the motor will not dislocated. Remove the coupling
bolts for mechanical connection.
(1) Motor
Check the motor model type and rated output [kW].
Key input
LC display (example)
Remark
The sequence is displayed.
MODE
MODE
MODE
MODE
ESC
ESC
ESC
ESC
By the ESC key, select the sub mode.
By
∧
key or
∨
key, select [Sn006]
SHIFT
SHIFT
SHIFT
SHIFT
ENT
ENT
ENT
ENT
Pressing the ENT key for at least 1 [sec] displays the motor model type.
GYC type (
“
C
”
of cubic) motor of 0.1 [kW] is displayed on the left example.
Summary of Contents for Faldic-a Series
Page 1: ...RYS V Type User s Manual MHT258a Engl...
Page 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Page 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Page 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Page 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...