MHT258a (Engl.)
4-9
(c) Wiring cable
If the optional encoder wiring cable is not used, use wiring with the following cable or equivalent.
•
Cross-link polyethylene insulated, vinyl sheath cable :
AWG No.25 / 2P+AWG No.23/2C(*), (twisted-pair cable), RMCV-SB (UL2464) type
The wiring length should be within 10[m] long.
•
Cross-link polyethylene insulated, vinyl sheath cable :
AWG No.25 / 2P+AWG No.16/2C(*), (twisted-pair cable), RMCV-SB (UL2464) type
(*) 2P (pairs), 2C (core) twisted-pair cable of different wire sizes. Use the enlarged sectional area of wires for power supply.
(d) Connection
It is not allowed to extend the wiring distance by connecting two or more cables of short wiring length.
CAUTION
Do not extend the wiring distance by connecting two or more encoder wiring cables.
A voltage drop by contact resistance of connector may stop the operation abruptly.
Remark : The wire size conversion between AWG and [mm] is as follows.
Sectional area
Gauge
Diameter
Circular mil
mm
2
A W G
mm G
mil
mm
CM
mm
2
1.4
55.12
1.400
3038
1.539
16
50.82
1.291
2583
1.309
1.2
47.24
1.200
2232
1.131
23
22.57
0.5773
509.4
0.2581
.55
21.65
0.5500
468.7
0.2376
24
20.10
0.5106
404.0
0.2047
.50
19.69
0.5000
387.7
0.1963
25
17.90
0.4547
320.4
0.1623
.45
17.72
0.4500
314.0
0.1590
Summary of Contents for Faldic-a Series
Page 1: ...RYS V Type User s Manual MHT258a Engl...
Page 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Page 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Page 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Page 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...