PowerConnect B-Series FCX Configuration Guide
675
53-1002266-01
Using FDP
23
To change the FDP hold time, enter a command such as the following at the global CONFIG level of
the CLI.
PowerConnect(config)# fdp holdtime 360
Syntax: [no] fdp holdtime
<secs>
The
<secs>
parameter specifies the number of seconds a Dell PowerConnect device that receives
an FDP update can hold the update before discarding it. You can specify from 10 – 255 seconds.
The default is 180 seconds.
Displaying FDP information
You can display the following FDP information:
•
FDP entries for Dell PowerConnect neighbors
•
Individual FDP entries
•
FDP information for an interface on the device you are managing
•
FDP packet statistics
NOTE
If the Dell PowerConnect device has intercepted CDP updates, then the CDP information is also
displayed.
Displaying neighbor information
To display a summary list of all the Dell PowerConnect neighbors that have sent FDP updates to this
Dell PowerConnect device, enter the following command.
Syntax: show fdp neighbor [ethernet
<port>
] [detail]
The ethernet
<port>
parameter lists the information for updates received on the specified port.
The detail parameter lists detailed information for each device.
The show fdp neighbor command, without optional parameters, displays the following information.
TABLE 118
Summary FDP and CDP neighbor information
This line...
Displays...
Device ID
The hostname of the neighbor.
Local Int
The interface on which this Dell PowerConnect device received an FDP
or CDP update for the neighbor.
Holdtm
The maximum number of seconds this device can keep the information
received in the update before discarding it.
PowerConnectA# show fdp neighbor
Capability Codes: R - Router, T - Trans Bridge, B - Source Route Bridge
S - Switch, H - Host, I - IGMP, r - Repeater
(*) indicates a CDP device
Device ID Local Int Holdtm Capability Platform Port ID
-------------- ------------ ------ ---------- ----------- -------------
PowerConnect B Eth 2/9 178 Router PowerConnect Rou Eth 2/9
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...