532
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Configuring MAC-based VLANs
15
When both features are configured on a port, a device connected to the port is authenticated as
follows.
1. MAC-based VLAN is performed on the device to authenticate the device MAC address.
2. If MAC-based VLAN is successful, the device then checks to see if the RADIUS server included
the Foundry-802_1x-enable VSA (described in
Table 90
) in the Access-Accept message that
authenticated the device.
3. If the Foundry-802_1x-enable VSA is not present in the Access-Accept message, or is present
and set to 1, then 802.1X authentication is performed for the device.
4. If the Foundry-802_1x-enable VSA is present in the Access-Accept message, and is set to 0,
then 802.1X authentication is skipped.
Configuring generic and Dell vendor-specific attributes on the RADIUS
server
If the RADIUS authentication process is successful, the RADIUS server sends an Access-Accept
message to the Dell PowerConnect device, authenticating the device. The Access-Accept message
includes Vendor-Specific Attributes (VSAs) that specify additional information about the device.
Add Dell vendor-specific attributes to your RADIUS server configuration, and configure the
attributes in the individual or group profiles of the devices that will be authenticated. Dell.
vendor-ID is 1991, vendor-type 1.
Table 89
lists generic RADIUS attributes.
Table 90
lists Dell
Vendor-Specific Attributes.
TABLE 89
Generic RADIUS attributes
Attribute name
Attribute ID
Data type
Optional or
mandatory
Description
Tunnel-Type
64
13
decimal
VLAN
Mandatory
RFC 2868.
Tunnel-Medium-Type
65
6
decimal
802
Mandatory
RFC 2868.
Tunnel-Private-Group-I
D
81
decimal
Mandatory
RFC 2868.
<vlan-id>
or U:
<vlan -id>
– a
MAC-based VLAN ID configured on the Dell
PowerConnect device.
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...