310
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Configuring VLAN-based static MAC entries
9
or
Syntax: [no] static-mac-address
<mac-addr>
ethernet [
<slotnum>
/]
<portnum>
to ethernet
[
<slotnum>
]
<portnum>
[priority
<num>
]
The
<slotnum>
parameter is required on chassis devices.
The
<portnum>
parameter is a valid port number.
The priority
<num>
is optional and can be a value from 0 – 7 (0 is lowest priority and 7 is highest
priority). The default priority is 0.
NOTE
The location of the static-mac-address command in the CLI depends on whether you configure
port-based VLANs on the device. If the device does not have more than one port-based VLAN (VLAN
1, which is the default VLAN that contains all the ports), the static-mac-address command is at the
global CONFIG level of the CLI. If the device has more than one port-based VLAN, then the
static-mac-address command is not available at the global CONFIG level. In this case, the command
is available at the configuration level for each port-based VLAN.
Configuring VLAN-based static MAC entries
You can configure a VLAN to drop packets that have a particular source or destination MAC
address.
You can configure a maximum of 2048 static MAC address drop entries on a Dell PowerConnect
device.
Use the CLI command show running-config to view the static MAC address drop entries currently
configured on the device.
Command syntax
To configure a VLAN to drop packets with a source or destination MAC address of 1145.5563.67FF,
enter the following commands.
PowerConnect(config)#vlan 2
PowerConnect(config-vlan-2)#static-mac-address 1145.5563.67FF drop
Syntax: [no] static-mac-address
<mac-addr>
drop
Use the no form of the command to remove the static MAC address drop configuration.
Clearing MAC address entries
You can remove learned MAC address entries from the MAC address table. The types of MAC
address can be removed are as follows:
•
All MAC address entries
•
All MAC address entries for a specified Ethernet port
•
All MAC address entries for a specified VLAN
•
All specified MAC address entry in all VLANs
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...