PowerConnect B-Series FCX Configuration Guide
935
53-1002266-01
Configuring OSPF
29
The stub
<cost>
parameter specifies an additional cost for using a route to or from this area and
can be from 1 through 16777215. There is no default. Normal areas do not use the cost
parameter.
The no-summary parameter applies only to stub areas and disables summary LSAs from being sent
into the area.
NOTE
You can assign one area on a router interface. For example, if the system or chassis module has 16
ports, 16 areas are supported on the chassis or module.
Assigning a Not-So-Stubby Area (NSSA)
The OSPF Not-So-Stubby Area (NSSA) feature enables you to configure OSPF areas that provide the
benefits of stub areas, but that also are capable of importing external route information. OSPF
does not flood external routes from other areas into an NSSA, but does translate and flood route
information from the NSSA into other areas such as the backbone.
NSSAs are especially useful when you want to summarize Type-5 External LSAs (external routes)
before forwarding them into an OSPF area. The OSPF specification (RFC 2328) prohibits
summarization of Type-5 LSAs and requires OSPF to flood Type-5 LSAs throughout a routing
domain. When you configure an NSSA, you can specify an address range for aggregating the
external routes that the NSSA's ABR exports into other areas.
The Dell implementation of NSSA is based on RFC 1587.
Figure 142
shows an example of an OSPF network containing an NSSA.
FIGURE 142
OSPF network containing an NSSA
This example shows two routing domains, a RIP domain and an OSPF domain. The ASBR inside the
NSSA imports external routes from RIP into the NSSA as Type-7 LSAs, which the ASBR floods
throughout the NSSA.
RIP Dom
a
in
L
a
yer 3
Switch
L
a
yer 3
Switch
L
a
yer 3
Switch
NSSA Are
a
1.1.1.1
Intern
a
l ASBR
OSPF ABR
OSPF Are
a
0
B
a
ckbone
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...