1412
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Syslog messages
41
Notification
OSPF virtual intf retransmit, rid
<router-id>
,
intf addr
<ip-addr>
, nbr rid <nbr-router-id>,
pkt type is
<pkt-type>
, LSA type
<lsa-type>
,
LSA id
<lsa-id>
, LSA rid <lsa-router-id>
An OSPF interface on the Dell
PowerConnect device has retransmitted a
Link State Advertisement (LSA).
The
<router-id>
is the router ID of the Dell
PowerConnect device.
The
<ip-addr>
is the IP address of the
interface on the Dell PowerConnect device.
The <nbr-router-id> is the router ID of the
neighbor router.
The
<packet-type>
can be one of the
following:
•
hello
•
database description
•
link state request
•
link state update
•
link state ack
•
unknown
The
<lsa-type>
is the type of LSA.
The
<lsa-id>
is the LSA ID.
The <lsa-router-id> is the LSA router ID.
Notification
OSPF virtual intf state changed,
rid
<router-id>
, area
<area-id>
,
nbr
<ip-addr>
, state
<ospf-state>
Indicates that the state of an OSPF virtual
routing interface has changed.
The
<router-id>
is the router ID of the router
the interface is on.
The
<area-id>
is the area the interface is in.
The
<ip-addr>
is the IP address of the OSPF
neighbor.
The
<ospf-state>
indicates the state to
which the interface has changed and can
be one of the following:
•
down
•
loopback
•
waiting
•
point-to-point
•
designated router
•
backup designated router
•
other designated router
•
unknown
TABLE 239
Syslog messages (Continued)
Message level
Message
Explanation
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...