PowerConnect B-Series FCX Configuration Guide
1
53-1002266-01
Chapter
1
Getting Familiar with Management Applications
Table 3
lists the individual Dell PowerConnect switches and the management application features
they support.
16
Using the management port
NOTE
The management port applies to PowerConnect B-Series FCX devices.
The management port is an out-of-band port that customers can use to manage their devices
without interfering with the in-band ports. The management port is widely used to download
images and configurations, for Telnet sessions, and for Web management.
For PowerConnect B-Series FCX devices, the MAC address for the management port is derived from
the base MAC address of the unit, plus the number of ports in the base module. For example, on a
48-port PowerConnect B-Series FCX standalone device, the base MAC address is
0000.1234.2200. The management port MAC address for this device would be 0000.1234.2200
plus 0x30, or 0000.1234.2230. The 0x30 in this case equals the 48 ports on the base module.
How the management port works
The following rules apply to management ports:
•
Only packets that are specifically addressed to the management port MAC address or the
broadcast MAC address are processed by the Layer 2 or Layer 3 switch. All other packets are
filtered out.
TABLE 3
Supported management application features
Feature
PowerConnect B-Series FCX
Management port
Yes
industry-standard Command Line
Interface (CLI), including support for:
•
Serial and Telnet access
•
Alias command
•
On-line help
•
Command completion
•
Scroll control
•
Line editing
•
Searching and filtering output
•
Special characters
Yes
Web-based GUI
•
Web Management Interface
Yes
Brocade Network Advisor
Yes
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...