PowerConnect B-Series FCX Configuration Guide
387
53-1002266-01
UDLD overview
11
If a port is disabled by UDLD, the change also is indicated in the output of the show interfaces brief
command. An example is given below.
If the port was already down before you enabled UDLD for the port, the port state is listed as None.
Syntax: show interfaces brief
Displaying information for a single port
To display detailed UDLD information for a specific port, enter a command such as the following.
Syntax: show link-keepalive [ethernet [
<slotnum>
/]
<portnum>
]
TABLE 68
CLI display of detailed UDLD information
This field...
Displays...
Current State
The state of the logical link. This is the link between this Dell PowerConnect port and the
Dell PowerConnect port on the other end of the link.
Remote MAC Addr
The MAC address of the port or device at the remote end of the logical link.
Local Port
The port number on this Dell PowerConnect device.
Remote Port
The port number on the Dell PowerConnect device at the remote end of the link.
Local System ID
A unique value that identifies this Dell PowerConnect device. The ID can be used by Dell
technical support for troubleshooting.
Remote System ID
A unique value that identifies the Dell PowerConnect device at the remote end of the link.
Packets sent
The number of UDLD health-check packets sent on this port.
Packets received
The number of UDLD health-check packets received on this port.
Transitions
The number of times the logical link state has changed between up and down.
Port blocking
Information used by Dell technical support for troubleshooting.
Link-vlan
The ID of the tagged VLAN in the UDLD packet.
BM disabled
Information used by Dell technical support for troubleshooting.
PowerConnect#show interfaces brief
Port Link State Dupl Speed Trunk Tag Priori MAC Name
1/1 Up
LK-DISABLE
None None None No level0 00e0.52a9.bb00
1/2 Down None None None None No level0 00e0.52a9.bb01
1/3 Down None None None None No level0 00e0.52a9.bb02
1/4 Down None None None None No level0 00e0.52a9.bb03
PowerConnect#show link-keepalive ethernet 4/1
Current State : up Remote MAC Addr : 00e0.52d2.5100
Local Port : 4/1 Remote Port : 2/1
Local System ID : e0927400 Remote System ID : e0d25100
Packets sent : 254 Packets received : 255
Transitions : 1 Link-vlan : 100
Port blocking : No BM disabled : No
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...