Displaying multi-device port authentication information
36
Displaying multi-device port authentication information
for a port
To display a summary of Multi-Device Port Authentication for ports on a device, enter the following
command
Syntax: show auth-mac-address ethernet
<port>
Table 229
explains the information in the output.
Displaying multi-device port authentication settings
and authenticated MAC addresses
To display the multi-device port authentication settings and authenticated MAC addresses for a
port where the feature is enabled, enter the following command.
Syntax: show auth-mac-address [detail] [ethernet
<port>
]
Specify the
<port>
variable in the following formats:
•
PowerConnect B-Series FCX stackable switches –
<stack-unit/slotnum/portnum>
TABLE 229
Output of show auth-mac-address
This field...
Displays...
MAC Address
The MAC addresses learned on the port. If the packet for which multi-device port
authentication was performed also contained an IP address, the IP address is also
displayed.
Port
ID of the port on which the MAC address was learned.
VLAN
VLAN of which the port is a member.
Authenticated
Whether the MAC address has been authenticated by the RADIUS server.
Time
The time the MAC address was authenticated. If the clock is set on the Dell PowerConnect
device, then the actual date and time are displayed. If the clock has not been set, the time is
displayed relative to when the device was last restarted.
Age
The age of the MAC address entry in the authenticated MAC address list.
Dot1x
Indicates if 802.1X authentication is enabled or disabled for the MAC address
PowerConnect#show auth-mac-addresses ethernet 18/1
-------------------------------------------------------------------------------
MAC Address Port Vlan Authenticated Time Age Dot1x
-------------------------------------------------------------------------------
000f.ed00.0001 18/1 87 Yes 00d01h03m17s Ena Ena
000f.ed00.012d 18/1 87 Yes 00d01h03m17s Ena Ena
000f.ed00.0321 18/1 87 No 00d01h03m17s H52 Ena
000f.ed00.0259 18/1 87 No 00d01h03m17s H52 Ena
000f.ed00.0065 18/1 87 Yes 00d01h03m17s Ena Ena
000f.ed00.0385 18/1 87 No 00d01h03m17s H52 Ena
000f.ed00.0191 18/1 87 Yes 00d01h03m17s Ena Ena
000f.ed00.02bd 18/1 87 No 00d01h03m17s H52 Ena
000f.ed00.00c9 18/1 87 No 00d01h03m17s H52 Ena
000f.ed00.01f5 18/1 87 Yes 00d01h03m17s Ena Ena
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...