1170
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Configuring TACACS/ security
32
•
You can configure the Dell PowerConnect device to authenticate using a TACACS or
server, not both.
TACACS configuration procedure
Follow the procedure given below for TACACS configurations.
1. Identify TACACS servers. Refer to
“Identifying the TACACS/ servers”
on page 1170.
2. Set optional parameters. Refer to
“Setting optional TACACS/ parameters”
on
page 1172.
3. Configure authentication-method lists. Refer to
“Configuring authentication-method lists for
TACACS/”
on page 1173.
configuration procedure
Follow the procedure given below for configurations.
1. Identify servers. Refer to
“Identifying the TACACS/ servers”
on page 1170.
2. Set optional parameters. Refer to
“Setting optional TACACS/ parameters”
on
page 1172.
3. Configure authentication-method lists. Refer to
“Configuring authentication-method lists for
TACACS/”
on page 1173.
4. Optionally configure authorization. Refer to
“Configuring authorization”
on
page 1175.
5. Optionally configure accounting. Refer to
“Configuring accounting”
on
page 1178.
Enabling TACACS
TACACS is disabled by default. To configure TACACS/ authentication parameters, you must
enable TACACS by entering the following command.
PowerConnect(config)#enable snmp config-tacacs
Syntax: [no] enable snmp
<config-radius
|
config-tacacs>
The
<config-radius>
parameter specifies the RADIUS configuration mode. RADIUS is disabled by
default.
The
<config-tacacs>
parameter specifies the TACACS configuration mode. TACACS is disabled by
default.
Identifying the TACACS/ servers
To use TACACS/ servers to authenticate access to a Dell PowerConnect device, you must
identify the servers to the Dell PowerConnect device.
For example, to identify three TACACS/ servers, enter commands such as the following.
PowerConnect(config)#tacacs-server host 207.94.6.161
PowerConnect(config)#tacacs-server host 207.94.6.191
PowerConnect(config)#tacacs-server host 207.94.6.122
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...