932
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Configuring OSPF
29
Interface parameters:
•
Assign interfaces to an area.
•
Define the authentication key for the interface.
•
Change the authentication-change interval
•
Modify the cost for a link.
•
Modify the dead interval.
•
Modify MD5 authentication key parameters.
•
Modify the priority of the interface.
•
Modify the retransmit interval for the interface.
•
Modify the transit delay of the interface.
NOTE
When using the CLI, you set global level parameters at the OSPF CONFIG level of the CLI. To reach
that level, enter router ospf… at the global CONFIG level. Interface parameters for OSPF are set at
the interface CONFIG level using the CLI command, ip ospf…
When using the Web Management Interface, you set OSPF global parameters using the OSPF
configuration panel. All other parameters are accessed through links accessed from the OSPF
configuration sheet.
Enabling OSPF on the router
When you enable OSPF on the router, the protocol is automatically activated. To enable OSPF on
the router, enter the following CLI command.
PowerConnect(config)#router ospf
This command launches you into the OSPF router level where you can assign areas and modify
OSPF global parameters.
Syntax: router ospf
Note regarding disabling OSPF
If you disable OSPF, the Layer 3 Switch removes all the configuration information for the disabled
protocol from the running-config. Moreover, when you save the configuration to the startup-config
file after disabling one of these protocols, all the configuration information for the disabled protocol
is removed from the startup-config file.
NOTE
If you do not want to delete the OSPF configuration information, use the CLI command clear ip ospf
all instead of no router ospf. Refer to
“Resetting OSPF”
on page 933.
When you enter the no router ospf command, the CLI displays a warning message such as the
following.
PowerConnect(config-ospf-router)#no router ospf
router ospf mode now disabled. All ospf config data will be lost when writing to
flash!
The Web Management Interface does not display a warning message.
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...