1414
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Syslog messages
41
Notification
VRRP intf state changed,
intf
<portnum>
, vrid <virtual-router-id>,
state
<vrrp-state>
A state change has occurred in a Virtual
Router Redundancy Protocol (VRRP)
interface.
The
<portnum>
is the port.
The <virtual-router-id> is the virtual router
ID (VRID) configured on the interface.
The
<vrrp-state>
can be one of the
following:
•
init
•
master
•
backup
•
unknown
Warning
DOT1X security violation at port
<portnum>
,
malicious mac address detected:
<mac-address>
A security violation was encountered at the
specified port number.
Warning
Dup IP
<ip-addr>
detected, sent from MAC
<mac-addr>
interface
<portnum>
Indicates that the Dell PowerConnect device
received a packet from another device on
the network with an IP address that is also
configured on the Dell PowerConnect
device.
The
<ip-addr>
is the duplicate IP address.
The
<mac-addr>
is the MAC address of the
device with the duplicate IP address.
The
<portnum>
is the Dell PowerConnect
port that received the packet with the
duplicate IP address. The address is the
packet source IP address.
Warning
IGMP/MLD no hardware vidx, broadcast to
the entire vlan. rated limited number
IGMP or MLD snooping has run out of
hardware application VLANs. There are
4096 application VLANs per device. Traffic
streams for snooping entries without an
application VLAN are switched to the entire
VLAN and to the CPU to be dropped. This
message is rate-limited to appear a
maximum of once every 10 minutes. The
rate-limited number shows the number on
non-printed warnings.
Warning
IGMP/MLD:
<vlanId>(<portId>
) is V1 but
rcvd V2 from nbr
<ipAddr>
Port has received a query with a MLD
version that does not match the port MLD
version. This message is rated-limited to
appear a maximum of once every 10 hours.
Warning
Latched low RX Power | TX Power | TX Bias
Current | Supply Voltage | Temperature
warning
alarm | warning, port
<port-number>
The optical transceiver on the given port
has risen above or fallen below the alarm or
warning threshold.
TABLE 239
Syslog messages (Continued)
Message level
Message
Explanation
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...