1218
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
How 802.1X port security works
34
How 802.1X port security works
This section explains the basic concepts behind 802.1X port security, including device roles, how
the devices communicate, and the procedure used for authenticating clients.
NOTE
802.1X Port Security cannot be configured on MAC Port Security-enabled ports.
Device roles in an 802.1X configuration
The 802.1X standard defines the roles of
Client/Supplicant
,
Authenticator
, and
Authentication
Server
in a network.
The Client (known as a
Supplicant
in the 802.1X standard) provides username/password
information to the Authenticator. The Authenticator sends this information to the Authentication
Server. Based on the Client's information, the Authentication Server determines whether the Client
can use services provided by the Authenticator. The Authentication Server passes this information
to the Authenticator, which then provides services to the Client, based on the authentication result.
Figure 153
illustrates these roles.
FIGURE 153
Authenticator, client/supplicant, and authentication server in an 802.1X
configuration
Authenticator – The device that controls access to the network. In an 802.1X configuration, the
PowerConnect device serves as the Authenticator. The Authenticator passes messages between
the Client and the Authentication Server. Based on the identity information supplied by the Client,
and the authentication information supplied by the Authentication Server, the Authenticator either
grants or does not grant network access to the Client.
Client/Supplicant
RADIUS Server
(Authentication Server)
Switch
(Authenticator)
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...