1266
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Configuring the MAC port security feature
35
PowerConnect(config)#interface ethernet 7/11
PowerConnect(config-if-e1000-7/11)#port security
PowerConnect(config-port-security-e1000-7/11)#age 10
Syntax: [no] age
<minutes>
The
<minutes>
variable specifies a range from 0 through 1440 minutes.The default is 0 (never age
out secure MAC addresses).
Specifying secure MAC addresses
You can configure secure MAC addresses on tagged and untagged interfaces.
On an untagged interface
To specify a secure MAC address on an untagged interface, enter commands such as the following.
PowerConnect(config)#interface ethernet 7/11
PowerConnect(config-if-e1000-7/11)#port security
PowerConnect(config-port-security-e1000-7/11)#secure-mac-address 0050.DA18.747C
Syntax: [no] secure-mac-address
<mac-address>
On a tagged interface
When specifying a secure MAC address on a tagged interface, you must also specify the VLAN ID.
To do so, enter commands such as the following.
PowerConnect(config)#interface ethernet 7/11
PowerConnect(config-if-e1000-7/11)#port security
PowerConnect(config-port-security-e1000-7/11)#secure-mac-address 0050.DA18.747C 2
Syntax: [no] secure-mac-address
<mac-address>
<vlan-ID>
NOTE
If MAC port security is enabled on a port and you change the VLAN membership of the port, make
sure that you also change the VLAN ID specified in the secure-mac-address configuration statement
for the port.
When a secure MAC address is applied to a tagged port, the VLAN ID is generated for both tagged
and untagged ports. When you display the configuration, you will see an entry for the secure MAC
addresses. For example, you might see an entry similar to the following line.
secure-mac-address 0000.1111.2222 10
This line means that MAC address 0000.1111.2222 on VLAN 10 is a secure MAC address.
Autosaving secure MAC addresses to the
startup-config file
Learned MAC addresses can automatically be saved to the startup-config file at specified intervals.
For example, to automatically save learned secure MAC addresses every 20 minutes, enter the
following commands.
PowerConnect(config)#port security
PowerConnect(config-port-security)#autosave 20
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...