804
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Configuring IP parameters – Layer 3 Switches
26
For example, if the domain “ds.company.com” is defined on a Layer 2 Switch or Layer 3 Switch and
you want to initiate a ping to “mary”. You need to reference only the host name instead of the host
name and its domain name. For example, you could enter the following command to initiate the
ping.
U:> ping mary
The Layer 2 Switch or Layer 3 Switch qualifies the host name by appending a domain name. For
example, mary.ds1.company.com. This qualified name is sent to the DNS server for resolution. If
there are four DNS servers configured, it is sent to the first DNS server. If the host name is not
resolved, it is sent to the second DNS server. If a match is found, a response is sent back to the
client with the host IP address. If no match is found, an “unknown host” message is returned.
(Refer to
Figure 127
.)
FIGURE 127
DNS resolution with one domain name
Defining a domain name
To define a domain to resolve host names, enter a command such as the following.
PowerConnect(config)# ip dns domain-name ds.company.com
Syntax: [no] ip dns domain-name
<domain-name>
Enter the domain name for
<domain-name>
.
1. Client
s
end
s
a
comm
a
nd to ping
"m
a
ry"
Dom
a
in n
a
me
eng.comp
a
ny.com i
s
config
u
red in the
device
DNS Server
s
with ho
s
t
n
a
me
s
a
nd IP
a
ddre
ss
e
s
config
u
red
DNS Server 1
DNS Server 2
DNS Server 3
DNS Server 4
2. Device
s
end
s
"m
a
ry.eng.comp
a
ny.com
to DNS
s
erver
s
for re
s
ol
u
tion.
4. If “m
a
ry.eng.comp
a
ny.com”
i
s
in the DNS
s
erver
s
, it
s
IP
a
ddre
ss
i
s
ret
u
rned. If it i
s
not
fo
u
nd,
a
“
u
nknown ho
s
t”
me
ssa
ge i
s
ret
u
rned.
3. Beginning with DNS Server 1,
DNS Server
s
a
re checked
in
s
eq
u
enti
a
l order to
s
ee if
“m
a
ry.eng.comp
a
ny.com”
i
s
config
u
red in the
s
erver.
Thi
s
s
erver h
as
“m
a
ry.eng.comp
a
ny.com”
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...