174
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
PowerConnect B-Series FCX hitless stacking
5
Enabling hitless stacking
Hitless stacking is disabled by default. To enable it, enable hitless failover as described in
“Enabling hitless failover”
on page 175.
Displaying hitless stacking status
You can use the show stack command to view whether or not hitless stacking is enabled. The
following example shows that hitless stacking is disabled.
Syntax: show stack
Displaying pending device roles
When hitless stacking is disabled, a priority change will trigger an election, but the newly-elected
winner will not assume its role until the entire stack is reloaded or hitless stacking is enabled.
You can use the show stack command to view pending device roles. The “Role” column displays the
current role for each unit. The “Comment” column displays the role that will take effect after a
reload or when hitless stacking is enabled.
PowerConnect#show stack
alone: standalone, D: dynamic config, S: static config
ID Type Role Mac Address Pri State Comment
2 S FCX648S member 0000.0000.0000 0 reserve
3 S FCX624 member 0024.3876.2640 0 remote Ready
5 S FCX624 standby 00e0.5200.0400 100 remote Ready
8 S FCX648 active 0024.3877.7980 128 local Ready
active standby
+---+ +---+ +---+
-2/1| 8 |2/2--2/2| 3 |2/1--2/1| 5 |2/2-
| +---+ +---+ +---+ |
| |
|-------------------------------------|
Standby u5 -
No hitless failover. Reason: hitless-failover not configured
PowerConnect#show stack
alone: standalone, D: dynamic config, S: static config
ID Type Role Mac Address Pri State Comment
2 S FCX648S member 0000.0000.0000 0 reserve
3 S FCX624 standby 0024.3876.2640 200 remote
Ready, active if reloaded
5 S FCX624 member 00e0.5200.0400 128 remote
Ready, standby if reloaded
8 S FCX648 active 0024.3877.7980 128 local
Ready, member if reloaded
active standby
+---+ +---+ +---+
-2/1| 8 |2/2--2/2| 3 |2/1--2/1| 5 |2/2-
| +---+ +---+ +---+ |
| |
|-------------------------------------|
Standby u3 - No hitless failover. Reason: hitless-failover not configured
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...