558
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Configuring extended numbered ACLs
16
•
echo-reply
•
information-request
•
log
•
mask-reply
•
mask-request
•
parameter-problem
•
redirect
•
source-quench
•
time-exceeded
•
timestamp-reply
•
timestamp-request
•
traffic policy
•
unreachable
•
<num>
The
<tcp/udp comparison operator>
parameter specifies a comparison operator for the TCP or
UDP port number. This parameter applies only when you specify tcp or udp as the IP protocol. For
example, if you are configuring an entry for HTTP, specify tcp eq http. You can enter one of the
following operators:
•
eq – The policy applies to the TCP or UDP port name or number you enter after eq.
•
established – This operator applies only to TCP packets. If you use this operator, the policy
applies to TCP packets that have the ACK (Acknowledgment) or RST (Reset) bits set on (set to
“1”) in the Control Bits field of the TCP packet header. Thus, the policy applies only to
established TCP sessions, not to new sessions. Refer to Section 3.1, “Header Format”, in RFC
793 for information about this field.
NOTE
This operator applies only to destination TCP ports, not source TCP ports.
•
gt – The policy applies to TCP or UDP port numbers greater than the port number or the
numeric equivalent of the port name you enter after gt.
•
lt – The policy applies to TCP or UDP port numbers that are less than the port number or the
numeric equivalent of the port name you enter after lt.
•
neq – The policy applies to all TCP or UDP port numbers except the port number or port name
you enter after neq.
•
range – The policy applies to all TCP or UDP port numbers that are between the first TCP or
UDP port name or number and the second one you enter following the range parameter. The
range includes the port names or numbers you enter. For example, to apply the policy to all
ports between and including 23 (Telnet) and 53 (DNS), enter the following: range 23 53. The
first port number in the range must be lower than the last number in the range.
The
<tcp/udp-port>
parameter specifies the TCP or UDP port number or well-known name. You can
specify a well-known name for any application port whose number is less than 1024. For other
application ports, you must enter the number. Enter “?” instead of a port to list the well-known
names recognized by the CLI.
The in parameter specifies that the ACL applies to incoming traffic on the interface to which you
apply the ACL. You can apply the ACL to an Ethernet port or a virtual interface.
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...