PowerConnect B-Series FCX Configuration Guide
53-1002266-01
SNMP version 3 traps
40
Backward compatibility with SMIv1 trap format
The Dell PowerConnect device will continue to support creation of traps in SMIv1 format, as before.
To allow the device to send notifications in SMIv2 format, configure the device as described above.
The default mode is still the original SMIv1 format.
Specifying an IPv6 host as an SNMP trap receiver
You can specify an IPv6 host as a trap receiver to ensure that all SNMP traps sent by the device will
go to the same SNMP trap receiver or set of receivers, typically one or more host devices on the
network. To do so, enter a command such as the following.
PowerConnect (config)#snmp-server host ipv6 2001:efff:89::13
Syntax: snmp-server host ipv6
<ipv6-address>
The
<ipv6-address>
must be in hexadecimal format using 16-bit values between colons as
documented in RFC 2373.
SNMP v3 over IPv6
Some PowerConnect devices support IPv6 for SNMP version 3.
Restricting SNMP Access to an IPv6 Node
You can restrict SNMP access so that the Dell PowerConnect device (including IronView Network
Manager) can only be accessed by the IPv6 host address that you specify. To do so, enter a
command such as the following .
PowerConnect (config)#snmp-client ipv6 2001:efff:89::23
Syntax: snmp-client ipv6
<ipv6-address>
The
<ipv6-address>
must be in hexadecimal format using 16-bit values between colons as
documented in RFC 2373.
Specifying an IPv6 host as an SNMP trap receiver
You can specify an IPv6 host as a trap receiver to ensure that all SNMP traps sent by the Dell
PowerConnect device will go to the same SNMP trap receiver or set of receivers, typically one or
more host devices on the network. To do so, enter a command such as the following .
PowerConnect(config)#snmp-server host ipv6 2001:efff:89::13
Syntax: snmp-server host ipv6
<ipv6-address>
The
<ipv6-address>
must be in hexadecimal format using 16-bit values between colons as
documented in RFC 2373.
Viewing IPv6 SNMP server addresses
Many of the existing show commands display IPv6 addresses for IPv6 SNMP servers. The following
example shows output for the show snmp server command.
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...