666
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Displaying IGMP snooping information
22
Syntax: show ip multicast resource
The following table describes the output from the show ip multicast resource command.
Displaying status of IGMP snooping traffic
To display status information for IGMP snooping traffic, enter the following command.
Syntax: show ip multicast traffic
The following table describes the information displayed by the show ip multicast traffic command.
Field
Description
alloc
The allocated number of units.
in-use
The number of units which are currently being used.
avail
The number of available units.
get-fail
This displays the number of resource failures.
NOTE: It is important to pay attention to this field.
limit
The upper limit of this expandable field. The limit of
multicast group
is configured by the
system-max igmp-max-group-addr command. The limit of
snoop mcache entry
is
configured by the system-max multicast-snoop-mcache command.
get-mem
The number of memory allocation. This number should continue to increase.
size
The size of a unit (in bytes).
init
The initial allocated amount of memory. More memory can be allocated if resources run out.
Available vidx
The output interface (OIF) port mask used by mcache. The entire device has a maximum of
4096 vidx. Different mcaches with the same OIF share the same vidx. If vidx is not available,
the stream cannot be hardware-switched.
Field
Description
Q
Query
Qry
General Query
QryV2
Number of general IGMPv2 queries received or sent.
QryV3
Number of general IGMPv3 queries received or sent.
G-Qry
Number of group-specific queries received or sent.
PowerConnect# show ip multicast traffic
IGMP snooping: Total Recv: 22, Xmit: 26
Q: query, Qry: general Q, G-Qry: group Q, GSQry: group-source Q, Mbr: member
Recv QryV2 QryV3 G-Qry GSQry MbrV2 MbrV3 Leave
VL1 0 0 0 0 4 0 0
VL70 18 0 0 0 0 0 0
Recv IsIN IsEX ToIN ToEX ALLOW BLOCK Pkt-Err
VL1 0 4 0 0 0 0 0
VL70 0 0 0 0 0 0 0
Send QryV2 QryV3 G-Qry GSQry MbrV2 MbrV3
VL1 0 0 8 0 0 0
VL70 0 0 0 0 0 18
VL70 pimsm-snooping, Hello: 12, Join/Prune: 9
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...