PowerConnect B-Series FCX Configuration Guide
637
53-1002266-01
Configuring mirroring on an Ironstack
20
Configuring mirroring on an Ironstack
You can configure mirroring on a Dell IronStack. An IronStack consists of up to 8 PowerConnect
B-Series FCX devices. The stack operates as a chassis. The following examples show how to
configure mirroring for ports that are on different members of a stack, and for ports that are on the
same stack member as the mirror port.
Configuration notes
The following mirroring configuration information applies to PowerConnect B-Series FCX devices
connected in an IronStack topology:
•
The input or output mirroring port can be on different ports.
•
An IronStack can have one mirroring port that monitors multiple ports, but cannot have
multiple mirror ports for one monitored port.
•
If the mirror port and the monitored ports are on different stack units, only one active mirror
port is allowed for the entire IronStack.
•
If the mirror port and the monitored ports are on the same port region, multiple active mirror
ports are allowed for the entire IronStack. Devices in an IronStack support 24 ports per port
region.
•
The maximum number of monitored VLANs on an IronStack is 8.
Example 1. Configuring mirroring for ports on different members in an IronStack
In this example, although 2 ports are configured as active ports, only one active mirror port (port
1/1/24) is allowed for the entire stack since the mirror ports and the monitored ports are on
different stack members.
PowerConnect(config)#mirror-port ethernet 1/1/24
PowerConnect(config)#mirror-port ethernet 2/1/24
PowerConnect(config)#interface ethernet 1/1/1
PowerConnect(config-if-e1000-1/1/1)#monitor ethernet 1/1/24 both
PowerConnect(config)#interface ethernet 2/1/1
PowerConnect(config-if-e1000-2/1/1)#monitor ethernet 1/1/24 both
PowerConnect(config)#int ethernet 4/1/1
PowerConnect(config-if-e1000-4/1/1)#monitor ethernet 1/1/24 both
Example 2. Configuring mirroring for ports on the same stack member in an
IronStack
PowerConnect(config)#mirror-port ethernet 1/1/24
PowerConnect(config)#mirror-port ethernet 2/1/24
PowerConnect(config)#mirror-port ethernet 3/1/24
PowerConnect(config)#mirror-port ethernet 4/1/24
PowerConnect(config)#interface ethernet 1/1/1
PowerConnect(config-if-e1000-1/1/1)#monitor ethernet 1/1/24 both
PowerConnect(config)#interface ethernet 2/1/1
PowerConnect(config-if-e1000-2/1/1)#monitor ethernet 2/1/24 both
PowerConnect(config)#int ethernet 4/1/1
PowerConnect(config-if-e1000-4/1/1)#monitor ethernet 4/1/24 both
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...