PowerConnect B-Series FCX Configuration Guide
977
53-1002266-01
Displaying OSPF information
29
Syntax: show ip ospf database external-link-state [advertise
<num>
] | [link-state-id
<ip-addr>
] |
[router-id
<ip-addr>
] | [sequence-number
<num(Hex)>
] | [status
<num>
]
To determine an external LSA or other type of LSA index number, enter one of the following
commands to display the appropriate LSA table:
•
show ip ospf database link-state advertise
<num>
– This command displays the data in the
packet for the specified LSA.
•
show ip ospf database external-link-state advertise
<num>
– This command displays the data
in the packet for the specified external LSA.
For example, to determine an external LSA index number, enter the following command.
Displaying OSPF virtual neighbor information
To display OSPF virtual neighbor information, enter the following command at any CLI level.
PowerConnect#show ip ospf virtual-neighbor
Syntax: show ip ospf virtual-neighbor [
<num>
]
The
<num>
parameter displays the table beginning at the specified entry number.
Displaying OSPF virtual link information
To display OSPF virtual link information, enter the following command at any CLI level.
PowerConnect#show ip ospf virtual-link
Syntax: show ip ospf virtual-link [
<num>
]
The
<num>
parameter displays the table beginning at the specified entry number.
Displaying OSPF ABR and ASBR information
To display OSPF ABR and ASBR information, enter the following command at any CLI level.
PowerConnect#show ip ospf database external-link-state advertise 3
Index Aging LS ID Router Netmask Metric Flag
3 619 1.27.250.0 192.85.0.3 fffffe00 000003e8 b500 0.0.0.0
LSA Header: age: 619, options: 0x02, seq-nbr: 0x80000003, length: 36
NetworkMask: 255.255.254.0
TOS 0: metric_type: 1, metric: 1000
forwarding_address: 0.0.0.0
external_route_tag: 0
PowerConnect#show ip ospf external-link-state
Index Aging LS ID Router Netmask Metric Flag
1 1809 1.18.81.0 103.103.103.6 ffffff00 000003e8 b500 0.0.0.0
2 8 1.27.250.0 103.103.103.6 fffffe00 000003e8 b500 0.0.0.0
3 8 3.215.0.0 103.103.103.6 ffff0000 000003e8 b500 0.0.0.0
4 18 1.33.192.0 102.102.102.6 fffffc00 000003e8 b500 0.0.0.0
5 959 1.9.168.0 102.102.102.6 ffffff00 00002710 b500 0.0.0.0
6 1807 1.3.226.0 192.85.0.3 ffffff00 000003e8 b500 0.0.0.0
7 1809 1.6.197.0 192.85.3.3 ffffff00 000003e8 b500 0.0.0.0
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...