background image

 

 

 

 

 

 

 

(Revised 4-9-2013) 

                                                                                            

 

 

 

  

 

 

 

 

 

 
 

NT24k 

Managed Industrial  

Ethernet Switch 

 

 

 

      

User Manual & 

Installation 

Guide 

 

 
 
 
 
 
 

 

Summary of Contents for NT24k

Page 1: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide...

Page 2: ...ient 29 Web Software Configuration 31 Web Management 31 Web Management Product Information Page 32 Web Management Menu Structure 34 Configuration Page 35 Fault Page 36 File Transfer Page 38 System Pag...

Page 3: ...Managed Industrial Ethernet Switch User Manual Installation Guide Page 3 of 132 SNMP Trap Stations 90 VLAN 92 Help Overview 97 Help Other 99 Appendix A XML Configuration File Factory Defaults 103 N TR...

Page 4: ...al Ethernet Switch User Manual Installation Guide Page 4 of 132 NT24k Industrial Ethernet Switch Installation Guide The NT24k is available in three configurations and this document addresses all three...

Page 5: ...igabit 16 for the NT24k DR16 ports and offer a wide range of connectivity options including 100Base Gigabit fiber optic and copper options in rugged Rack Mount or DIN rail enclosures Designed to handl...

Page 6: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 6 of 132 NT24k Series Common Features Continued...

Page 7: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 7 of 132 NT24k Series Common Features Continued...

Page 8: ...Tron NT24k Rack Mounted Managed Industrial Ethernet Switch features connectivity for up to 24 Gigabit ports in a rugged 1U 19 rackmount enclosure Designed to handle the most demanding environments the...

Page 9: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 9 of 132 NT24k Rack Mount Continued...

Page 10: ...Managed Industrial Ethernet Switch User Manual Installation Guide Page 10 of 132 NT24k DR24 The NT24k DR24 Managed Industrial Ethernet Switch features connectivity for up to 24 Gigabit ports in a rug...

Page 11: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 11 of 132 NT24k DR24 Continued...

Page 12: ...naged Industrial Ethernet Switch User Manual Installation Guide Page 12 of 132 NT24k DR16 The N Tron NT24k DR16 Managed Industrial Ethernet Switch features connectivity for up to 16 Gigabit ports in a...

Page 13: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 13 of 132 NT24k DR16 Continued...

Page 14: ...the area is known to be non hazardous Connection or disconnection in an explosive atmosphere could result in an explosion NTCD CFG Configuration Device Ideal for saving or restoring switch configurat...

Page 15: ...ncluding but not limited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N Tron Corporation be liable for any incidental special indirect or conseque...

Page 16: ...n com E MAIL N TRON_Support n tron com ENVIRONMENTAL SAFETY WARNING The unit may become very hot to the touch in high temperature environments so extreme caution should be exercised in handling when e...

Page 17: ...Substitution of components may impair suitability for Class I Div 2 3 WARNING Explosion Hazard do not disconnect while circuit is live unless area is known to be non hazardous 4 WARNING Explosion Haza...

Page 18: ...wer cable before removing any enclosure panel UNPACKING Remove all the equipment from the packaging and store the packaging in a safe place File any damage claims with the carrier CLEANING Clean only...

Page 19: ...Module Required NTSFP TX Up to 16 NT24k SFP8 or NT24k DM8 NTSFP FX Up to 24 NT24k DM8 NTSFP SX Up to 24 NT24k SFP8 or NT24k DM8 NTSFP LX Up to 24 NT24k SFP8 or NT24k DM8 NOTE The RJ45 data ports have...

Page 20: ...Plug from the Power Input Header Install the DC Power Cables into the Plug observing polarity Plug the Voltage Input Plug back into the Power Input Header Tightening torque for the terminal block pow...

Page 21: ...Verify the Power LED stays ON When an AC Power supply is installed i e the AC option Use 12 24 gauge wire when connecting to the power supply NT24k Fault Pins The Fault pins on the back of the NT24k...

Page 22: ...mpleted To connect any port to another device end node Switch or Repeater use a standard Category 5E straight through or crossover cable with a minimum length of one meter and a maximum length of 100...

Page 23: ...isolated from chassis ground Therefore the user must not attempt to ground the switch to earth ground via the power supply In other N Tron switches it is common to use the V for the purpose of ground...

Page 24: ...t5e cables manufactured to EIA 568A or 568B specifications are required for use with N Tron Switches In the event all Cat5e patch cable distances are small i e All Ethernet devices are located in the...

Page 25: ...PPP Point to Point Protocol PPP allows any configuration and status that the browser does USB Cable Connect the USB port of your PC and the Switch using a standard USB cable You will require a cable...

Page 26: ...ins silent for a random amount of time back off before attempting to transmit again Full Duplex Full duplex operation allows simultaneous communication between a pair of stations using point to point...

Page 27: ...s forward unicast multicast and broadcast traffic only on LAN segments that serve the VLAN to which the traffic belongs A Default Virtual LAN VID 1 exists to which a port which is not a member of any...

Page 28: ...her than forwarding them from the root bridge RSTP also sends out new BPDUs every hello time RSTP interoperates with older STP switches by falling back to STP when the older BPDUs are detected on brid...

Page 29: ...sing all N Ring enabled switches in the ring a detailed ring map and fault location chart is also provided on the N Ring Manager s web browser N Ring status is also sent from the N Ring Manager to the...

Page 30: ...e limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not instal...

Page 31: ...oftware Configuration Web Management Enter the switch s IP address in any web browser and login to the web management feature of the NT24k The DHCP Client is enabled in factory defaults with 192 168 1...

Page 32: ...ain home page the administrator can see some basic information like what firmware revision the switch is running The firmware can be upgraded at a later time in the field using http The Product Inform...

Page 33: ...l Installation Guide Page 33 of 132 Version Build Date The firmware s build date Boot Loader The boot loader s software version Copyright The copyright URL The company s home page on the internet Swit...

Page 34: ...ctions are described in the rest of this section The use of each of these pages is also described in this section On the left is the basic navigation Below that the Advanced folder can be opened to se...

Page 35: ...tion device is installed the configuration will also be saved to the device Selecting the Restore button will discard all unsaved changes and load the most recently saved configuration settings Select...

Page 36: ...ed Contact The fault is indicated by opening or closing the contact switch Power AC Left Indicates low voltage on the left AC power supply Power AC Right Indicates low voltage on the right AC power su...

Page 37: ...the switch Looking from the front of the unit DC V1 and V2 are on the right side and DC V3 and V4 are on the left side If a low voltage DC power supply is installed these additional choices appear Po...

Page 38: ...tors to backup their configurations to a server offsite in case they need to reload their custom configurations at a later time Administrators can for example update the firmware in the field without...

Page 39: ...elected you can browse and select an image or configuration file to upgrade with Reference Appendix A XML Configuration File Factory Defaults NOTE THAT YOU MUST REBOOT THE SWITCH TO BEGIN RUNNING THE...

Page 40: ...ch User Manual Installation Guide Page 40 of 132 File Transfer continued On Export Saved Configuration from switch pressing the Configuration Settings hyperlink brings up the Windows utilities to spec...

Page 41: ...the device Gateway Contains the current Gateway of the device MAC Address MAC Address of the device System Up Time This parameter represents the total time count This time has elapsed since the switch...

Page 42: ...t ID Option used by DHCP clients to specify their unique identifier The identifier may be the MAC address switch name or entered as a text string or hex characters Fallback IP Address Contains the con...

Page 43: ...a username a password and the user s permissions user administrator User names may include all alphanumerical characters _ and and must be 3 to 15 characters long Passwords may include all printable c...

Page 44: ...nued In order to remove a user simply click on the Remove button at the bottom of the page Following the Remove button on the above example the administrator can remove a user by entering in the user...

Page 45: ...ble field displays the desired aging time for dynamically learned MAC addresses Inactive MAC addresses will be removed from the Hardware Address Entry Table after the aging time period has expired The...

Page 46: ...age above the administrator must enter a valid Multicast Group Address and associate it with a port number or list on the switch Once the administrator clicks on the Add button the changes will take e...

Page 47: ...ar on the main list and will show the associated ports that go along with that address Following the Remove button on the example above the administrator will be presented with a list of Multicast Gro...

Page 48: ...lay a list of MAC addresses that are associated with each respective port number This can be used to statically assign a MAC address access to a single port on the switch Following the Add button on t...

Page 49: ...ast Addresses Continued Once a staic MAC address has been added it will be displayed in a list on the main page under the Unicast Addresses tab Following the Remove button on the example above an admi...

Page 50: ...ategory will display the IGMP basic configuration settings By default IGMP is enabled Following the Modify button the administrator will see a list of configurable fields for the IGMP configuration On...

Page 51: ...2 IGMP Configuration Continued The IGMP Status pull down allows the user to enable or disable IGMP completely The Query Mode pull down allows the user to set query mode for Automatic the default On al...

Page 52: ...ed The Router Mode pull down allows the user to choose router mode Auto allows for dynamically detected and manually set router ports Manual allows only for manually set router ports None allows no ro...

Page 53: ...e Unused Groups is checked then unused IGMP Groups will be removed and traffic with those multicast addresses will be treated as normal multicast If unchecked then unused IGMP Groups are not removed a...

Page 54: ...based on the Group IP and the port that it is associated with Total Number of Active IP Group Memberships Total Number of Active Group IP Memberships based on the dotted quad aaa bbb ccc ddd view and...

Page 55: ...ps IGMP group data from egressing on the port unless a join to that specific IGMP group has come into the port IGMP controls Join Leave Query are still sent The factory default is that the Router Mult...

Page 56: ...Page 56 of 132 IGMP RFilter Continued Modifying rfilter port settings After pressing Modify the administrator can select which ports to identify as RFilter ports or choose all ports The administrator...

Page 57: ...net Switch User Manual Installation Guide Page 57 of 132 IGMP Routers The Routers tab under the IGMP category will display a list of Auto detected Router IPs and the port numbers that they are associa...

Page 58: ...ot have RSTP enabled on the N_Ring ports N Ring Manager will disable RSTP on the N Ring ports if necessary Other ports may have RSTP enabled 5 RSTP N Ring are different modes and cannot share links or...

Page 59: ...tion View will be Following the Modify button on the above example the administrator will see a pulldown of configurable choices for the N Ring configuration as below If N Ring Mode is Manager then a...

Page 60: ...wn if available In any event it is the lowest two installed ports Set Port set table index Ports Designated pair of N Ring ports To reassign different pairs the port sets containing those ports if any...

Page 61: ...l Ethernet Switch User Manual Installation Guide Page 61 of 132 N Ring Configuration Port Sets Continued Pressing Add on the page above yields The N Ring ports can be selected by pulldown In this mode...

Page 62: ...eep Alive Timeout The amount of time to wait in seconds to receive a keep alive request before switching from active member back to auto member The default is 31 The range is 15 to 300 seconds with an...

Page 63: ...efault is 1000 Sign On Match Packets The number of times the switch count must match before starting the sign on process The default is 3 Sign On Interval The interval of time to wait in milliseconds...

Page 64: ...d Industrial Ethernet Switch User Manual Installation Guide Page 64 of 132 N Ring Status If N Ring mode is inactive Auto Member the following data will be shown If N Ring mode is Active Auto Member th...

Page 65: ...If the MAC is selected more data will be retrieved and shown about the switch Switch No The number of the switch in the N Ring RM Ring Manager MAC Address The MAC Address of the switch IP Address The...

Page 66: ...ault N Ring Fault in red near the top of the display Note that the break is identified in red by switches and ports In this case N Ring manager A2 to N Ring active member Switch Number 1 TX2 is broken...

Page 67: ...e status Enabled or Disabled and the interval between packets Following the Modify button on the above example the administrator can modify the variable to change the frequency with which N View repor...

Page 68: ...User Manual Installation Guide Page 68 of 132 N View Ports The Ports tab under the N View category will display a list of all the configured ports on the NT24k unit along with the ports transmitting N...

Page 69: ...nued Following the Modify button on the above example the administrator can modify these two variables to enable or disable N View related multicast out of the port and if MIB stats are sent out for t...

Page 70: ...ge 70 of 132 Ports Configuration The Configuration tab under the Ports category will show a detailed overview of all the ports on the switch The administrator can view ports that are possible to insta...

Page 71: ...status of a port It may contain Disable Discarding Learning Forwarding PVID This configurable field displays the existing port VLAN ID setting The allowable range is 1 4094 Trunk ID When the port is a...

Page 72: ...lays the status including the list of Source Ports and the Destination Port that the Sources are being mirrored to Using the Modify button you can enable the status of port mirroring and select source...

Page 73: ...ss frame s IEEE802 1p User Priority value if needed based on the QOS settings and the User Priority value if any in the ingress frame Both the internal port priority setting and egress frame User Prio...

Page 74: ...ttings see QOS SELECTION CHART below The default value is enabled Include 802 1p This configurable field displays the status of whether or not to include the ingress frame s IEEE802 1p User Priority v...

Page 75: ...t for each of Broadcast Multicast Unknown Unicast and Known Unicast A packet type will be affected when the checkbox is selected if it exceeds the total number of packets subject to the ingress rate l...

Page 76: ...e example the administrator can modify the Pass Rate Percentage for each and every port The administrator can view ports that are possible to install Modules currently installed or currently linked up...

Page 77: ...uide Page 77 of 132 Ports Status Statistics Displays the MIB counters for the selected port specified by the Port pull down menu The Clear button will reset all counters for the selected port The Clea...

Page 78: ...Managed Industrial Ethernet Switch User Manual Installation Guide Page 78 of 132 Ports Status Utilization Shows a bandwidth percentage graph of all the ports The graph is scaled based on the Scale pu...

Page 79: ...ic characters and the special characters _ and Trunk Ports The ports associated with the trunk Trunk Status The existing status of the trunk It can be either enabled or disabled Notes 1 All ports in t...

Page 80: ...age 80 of 132 Ports Trunking Continued By selecting the Modify button you can then add delete or modify a trunk group By selecting Add you can first decide to view ports that are possible to install M...

Page 81: ...Guide Page 81 of 132 Ports Trunking Continued By selecting a trunk ID hyperlink from the Port Trunking Configuration View you can first decide to view ports that are possible to install Modules curre...

Page 82: ...mation and making configuration changes by using a web browser PPP mode is entered by using the PPP command on the console To change from PPP to CLI mode you must reboot the switch Console Mode CLI Th...

Page 83: ...ent modes and cannot share links or segments If a port is both an RSTP port and an active N Ring port then the port will be disabled for RSTP 2 Do not create redundant links unless either RSTP or N Ri...

Page 84: ...time spent in seconds by legacy STP Bridges in transitioning Root and Designated Ports to Forwarding This delays Port transitions until other bridges have received spanning tree information Max Age Se...

Page 85: ...s bridge is the Root Bridge or is attempting to become the Root Bridge This is the time spent in seconds by legacy STP Bridges in transitioning Root and Designated Ports to Forwarding This delays Port...

Page 86: ...2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 86 of 132 RSTP Bridge Continued The administrator can modify the Bridge parameters by pressing the Modify button on th...

Page 87: ...on that VLAN This will show information such as the Path Cost and the Port State If the switch sees a redundant path it will put the port with the highest Path Cost into Blocking mode where it will di...

Page 88: ...is Disabled Auto Edge Whether or not to use a short timeout when waiting for BPDUs before determining that this is an Edge Port if no BPDUs are received It may have to be disabled for a very large net...

Page 89: ...ts Only alphanumeric characters are allowed The default is public Read Write Community Name This configurable field represents the Authorized Community Name for SNMP Set requests Only alphanumeric cha...

Page 90: ...NMP Ttap Stations is done via this page IP Address This field represents the IP Address of the Management Station to be sent SNMP Traps Parameter This field represents the Target Parameter entry TRAPv...

Page 91: ...ser parameters are shown here for reference only as they are necessary for connecting to the switch securely using an SNMP V3 client when in defaults The default user and other users can be added dele...

Page 92: ...her or not to replace the VID tag of ingress frames with the port s default VID PVID Discard Untagged Frames For Ports Specifies whether or not untagged ingress frames are dropped by the selected port...

Page 93: ...ts Specifies whether or not to set the PVID of the member ports to this VLAN ID Remove Ports From Default VLAN When Added To This VLAN Specifies whether or not to remove ports from the Default VLAN wh...

Page 94: ...d Industrial Ethernet Switch User Manual Installation Guide Page 94 of 132 VLAN Continued Then you can specify general VLAN changes as below in the top frame Pressing Delete in the lower frame of the...

Page 95: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 95 of 132 VLAN Continued Pressing Add on the screen above allows entry of a new VLAN...

Page 96: ...2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 96 of 132 VLAN Continued Selecting the Port Number hyperlink in the lower frame of the screen two above allows changes...

Page 97: ...ernet Switch User Manual Installation Guide Page 97 of 132 Help Overview When the Overview tab of the Help menu is clicked on you will see the Overview page that will have some basic definitions and m...

Page 98: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 98 of 132 Help Overview Continued...

Page 99: ...l Installation Guide Page 99 of 132 Help Other This section provides information about fields or links in the top right corner of the page Specific help can be had using the left hand navigation as sh...

Page 100: ...ide Page 100 of 132 CLI Commands The CLI contains some status and configuration capability The default user password is admin The default password to enter privileged mode is admin Each command includ...

Page 101: ...T24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 101 of 132 CLI Commands Continued Set IP Mode to static Show the static IP Set a static IP mask and gateway are optional Sav...

Page 102: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 102 of 132 CLI Commands Continued Reboot...

Page 103: ...MulticastFilters UnicastFilters UnicastFilters BridgingConfig BridgingGroup Debug Debug FaultGroup FaultConfig ConfigFaults Fault Contact Disabled Contact Id 0 Id Led Disabled Led Web Disabled Web Fau...

Page 104: ...sabled Web Fault Fault Contact Enabled Contact Id 7 Id Led Enabled Led Web Enabled Web Fault Fault Contact Enabled Contact Id 8 Id Led Enabled Led Web Enabled Web Fault Fault Contact Enabled Contact I...

Page 105: ...mpConfig ManualRouterPorts None ManualRouterPorts QuerryMode Auto QuerryMode RemoveUnusedGroups Enabled RemoveUnusedGroups RFilterPorts All RFilterPorts RouterMode Auto RouterMode Status Enabled Statu...

Page 106: ...ealthyMs SignOnMatch 3 SignOnMatch StatusRefreshRate 6 StatusRefreshRate VlanId 3333 VlanId VlanTagged Tagged VlanTagged NringConfig NringGroup NViewGroup NViewConfig Interval 5 Interval SendAutocastP...

Page 107: ...tatus Enabled AdminStatus AutoNegotiate Enabled AutoNegotiate CrossOver Auto CrossOver Duplex Full Duplex FlowControl Disabled FlowControl PortNumber A3 PortNumber PortUsageAlarms UsageAlarmHigh 100 U...

Page 108: ...1 QosPriorityValue Speed 1000 Speed Port Port AdminStatus Enabled AdminStatus AutoNegotiate Enabled AutoNegotiate CrossOver Auto CrossOver Duplex Full Duplex FlowControl Disabled FlowControl PortNumbe...

Page 109: ...sDSCP Enabled QosDSCP QosPriorityValue 1 QosPriorityValue Speed 1000 Speed Port Port AdminStatus Enabled AdminStatus AutoNegotiate Enabled AutoNegotiate CrossOver Auto CrossOver Duplex Full Duplex Flo...

Page 110: ...larms PVID 1 PVID Qos8021p Enabled Qos8021p QosDSCP Enabled QosDSCP QosPriorityValue 1 QosPriorityValue Speed 1000 Speed Port Port AdminStatus Enabled AdminStatus AutoNegotiate Enabled AutoNegotiate C...

Page 111: ...geAlarmHigh UsageAlarmLow 0 UsageAlarmLow PortUsageAlarms PVID 1 PVID Qos8021p Enabled Qos8021p QosDSCP Enabled QosDSCP QosPriorityValue 1 QosPriorityValue Speed 1000 Speed Port Port AdminStatus Enabl...

Page 112: ...rtNumber PortUsageAlarms UsageAlarmHigh 100 UsageAlarmHigh UsageAlarmLow 0 UsageAlarmLow PortUsageAlarms PVID 1 PVID Qos8021p Enabled Qos8021p QosDSCP Enabled QosDSCP QosPriorityValue 1 QosPriorityVal...

Page 113: ...Duplex FlowControl Disabled FlowControl PortNumber C4 PortNumber PortUsageAlarms UsageAlarmHigh 100 UsageAlarmHigh UsageAlarmLow 0 UsageAlarmLow PortUsageAlarms PVID 1 PVID Qos8021p Enabled Qos8021p Q...

Page 114: ...toNegotiate CrossOver Auto CrossOver Duplex Full Duplex FlowControl Disabled FlowControl PortNumber C7 PortNumber PortUsageAlarms UsageAlarmHigh 100 UsageAlarmHigh UsageAlarmLow 0 UsageAlarmLow PortUs...

Page 115: ...3 RateLimit UnknownUnicast Disabled UnknownUnicast Limit Limit Broadcast Enabled Broadcast KnownUnicast Disabled KnownUnicast Multicast Disabled Multicast PortNumber A3 PortNumber RateLimit 3 RateLim...

Page 116: ...er RateLimit 3 RateLimit UnknownUnicast Disabled UnknownUnicast Limit Limit Broadcast Enabled Broadcast KnownUnicast Disabled KnownUnicast Multicast Disabled Multicast PortNumber B1 PortNumber RateLim...

Page 117: ...knownUnicast Disabled UnknownUnicast Limit Limit Broadcast Enabled Broadcast KnownUnicast Disabled KnownUnicast Multicast Disabled Multicast PortNumber B7 PortNumber RateLimit 3 RateLimit UnknownUnica...

Page 118: ...knownUnicast Limit Limit Broadcast Enabled Broadcast KnownUnicast Disabled KnownUnicast Multicast Disabled Multicast PortNumber C5 PortNumber RateLimit 3 RateLimit UnknownUnicast Disabled UnknownUnica...

Page 119: ...tpMac Auto AdminPtpMac AutoEdge Enabled AutoEdge PathCost Auto PathCost PortNumber A1 PortNumber PortPriorityStep 128 PortPriorityStep VlanId 1 VlanId Port Port AdminEdge Disabled AdminEdge AdminPtpMa...

Page 120: ...uto PathCost PortNumber A6 PortNumber PortPriorityStep 128 PortPriorityStep VlanId 1 VlanId Port Port AdminEdge Disabled AdminEdge AdminPtpMac Auto AdminPtpMac AutoEdge Enabled AutoEdge PathCost Auto...

Page 121: ...lanId Port Port AdminEdge Disabled AdminEdge AdminPtpMac Auto AdminPtpMac AutoEdge Enabled AutoEdge PathCost Auto PathCost PortNumber B4 PortNumber PortPriorityStep 128 PortPriorityStep VlanId 1 VlanI...

Page 122: ...dge PathCost Auto PathCost PortNumber C1 PortNumber PortPriorityStep 128 PortPriorityStep VlanId 1 VlanId Port Port AdminEdge Disabled AdminEdge AdminPtpMac Auto AdminPtpMac AutoEdge Enabled AutoEdge...

Page 123: ...ityStep 128 PortPriorityStep VlanId 1 VlanId Port Port AdminEdge Disabled AdminEdge AdminPtpMac Auto AdminPtpMac AutoEdge Enabled AutoEdge PathCost Auto PathCost PortNumber C7 PortNumber PortPriorityS...

Page 124: ...otifyView Prefix Prefix ReadView mibView ReadView Status 1 Status Storage 3 Storage WriteView WriteView V3Access V3Access GroupName mibNotify GroupName Level 1 Level Match 1 Match Model 0 Model Notify...

Page 125: ...Name set SecurityName Status 1 Status Storage 3 Storage TransportTag TransportTag V3Community V3Community CommunityName public CommunityName ContextEngineId 80006edd030007af7d9560 ContextEngineId Cont...

Page 126: ...ibRead GroupName Model 1 Model Status 1 Status Storage 3 Storage UserName get UserName V3Group V3Group GroupName mibRead GroupName Model 2 Model Status 1 Status Storage 3 Storage UserName get UserName...

Page 127: ...80006edd030007af7d9560 ContextEngineId ContextName ContextName MultipleTargetOut group1 MultipleTargetOut ProxyName trap_proxy ProxyName ProxyType 3 ProxyType SingleTargetOut SingleTargetOut Status 1...

Page 128: ...SingleTargetOut addr1 SingleTargetOut Status 1 Status Storage 3 Storage TargetParamsIn NoAuthNoPriv md5 TargetParamsIn V3Proxy V3Proxies V3TargetAddresses TargetAddresses TargetAddresses TargetParame...

Page 129: ...SecName Status 1 Status Storage 3 Storage TargetParameter TargetParameters V3TargetAddresses V3Users V3User AuthKey 76d0e46ae1b32272fc21083d89678840 AuthKey AuthPassword AuthPassword AuthProt 1 AuthPr...

Page 130: ...ta Data Type SwitchName Type ClientId FallbackEnable Enabled FallbackEnable FallbackGateway 0 0 0 0 FallbackGateway FallbackIPAddress 192 168 1 201 FallbackIPAddress FallbackSubnet 255 255 255 0 Fallb...

Page 131: ...me admin Username WriteAccess 4 WriteAccess User Users UserConfig UserGroup VlanGroup VlanConfig IngressDiscardUntagged None IngressDiscardUntagged IngressReplaceVID Disabled IngressReplaceVID Ingress...

Page 132: ...for the replacement product at list price WARRANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT O...

Reviews: