(Revised 4-9-2013) NT24k Managed Industrial Ethernet Switch User Manual & Installation Guide Page 36 of 132
Fault Page
The page provides configurable selections indicating the ways to notify when a Power, N-Ring Manager,
Port Usage, Temperature, or Configuration Device fault occurs. In each case, the notification may consist of
any combination of the options: Show Web, Show LED, and Contact.
Fault Contact:
Determines if the fault relay is normally open (Close on Fault) or normally
closed (Open on Fault).
Show Web:
The fault is displayed on the browser pages.
Show LED:
The fault is indicated on the Power LED as red.
Contact:
The fault is indicated by opening or closing the contact switch.
Power AC (Left):
Indicates low voltage on the left AC power supply.
Power AC (Right):
Indicates low voltage on the right AC power supply.
The location of a power supply is based on the left or right hand side when viewing
from the front of the switch. Looking from the front of the unit: AC1 is on the right
side, and/or AC2 is on left side.
Port Usage Fault:
Indicates that the port usage, for one or more ports, is below the Usage Alarm Low
setting, or above the Usage Alarm High setting (see Port Configuration View and
Port Utilization View).
Temperature:
Indicates that the temperature of the switch is outside of the configured limits.
Configuration Device:
Indicates that the configuration on an installed configuration device is invalid.