USER INSTRUCTIONS

Installation

Operation

Maintenance

PMV WS/WM Ultraswitch™

Switchbox

FCD PMENIM0010-02 - 06/19

Summary of Contents for PMV WM Ultraswitch

Page 1: ...USER INSTRUCTIONS Installation Operation Maintenance PMV WS WM Ultraswitch Switchbox FCD PMENIM0010 02 06 19 ...

Page 2: ...ltraSwitch nomenclature 5 5 5 WS WM UltraSwitch switch options 6 6 INSTALLATION 8 6 1 Wiring instructions 9 6 2 Cover and housing options 10 7 SWITCHES Certified 11 7 1 Installation in hazardous locations 11 7 2 Adjusting limit switches 11 7 3 Cam fine adjustment 11 7 4 Switch option specifications all 12 8 DIMENSIONS 14 9 SPARE PARTS 15 10 NOTES 15 CONTENTS FCD PMENIM0010 02 06 19 ...

Page 3: ... In case of discrepancies contact your nearest FLOWSERVE location Substitution of components may impair suitability for Div 2 locations Inspect periodically for degradation Replace parts if degradation is found Cleaning this housing by rubbing should be done in a non hazardous area Potential electrostatic charging hazard clean only with a damp cloth danger of propagating discharge All grounding an...

Page 4: ...eered resin 25 30 fiberglass filled or Transparent Polycarbonate Shaft Stainless Steel SS EN 2346 AISI 303 Cams Splines Nylon Terminal Block Nylon Internal Brackets Nylon Aluminum or Stainless Steel All Internal Fasteners Stainless Steel All External Fasteners Stainless Steel All Molded in Fasteners Anodized Aluminum Indicators Polycarbonate or PA66 5 3 Product label Exemple Product name and model...

Page 5: ... entries D Number of conduit entries 2 2 conduit entries 4 4 conduit entries 2 according to C entries opposite side with different type of threading E Body material A Aluminum R Engineered resin F Cover material A Aluminum R Engineered resin P Polycarbonate Cover clear G Indicator 1 No indicator 2 Flat Arrow Indicator Yellow Black H Black Yellow UltraDome U Standard UltraDome Red Close Green Open ...

Page 6: ...5A 140 VAC 0 25A 200 VDC 1A 50 VDC 50 W Max contact rating P5 A B C SPDT Proximity Hamlin 0 25A 120 VAC 0 25A 28 VDC 3 W Max PE A B C SPDT Sabre Proximity Flowserve 1A 120 VAC 1A 24 VDC PP C SPDT Phazer Proximity Flowserve 3A 120 VAC 2A 24 VDC PT A B C SPST BRS Proximity Flowserve 3A 120 VAC 0 5 24 VDC N8 A Solid State Proximity PF NJ2 V3 N NAMUR NC Sensor 8 VDC NP A Solid State Proximity PF SJ3 5...

Page 7: ...page 5 2 Some models have more than two open terminal locations open as standard Consult factory for details Code Certificate A ATEX II 1G Ex ia IIC T4 T5 T6 ATEX II 1G Ex ia IIB T4 T5 T6 ATEX II 1D ta IIIC T80 C T500 85 C Da IP66 67 B cCSAus IS C cCSAus NI FCD PMENIM0010 02 06 19 ...

Page 8: ...w direct coupling to actuators without couplings reducing dead band Bolt bracket to actuator and WS WM Ultraswitch to bracket leaving bolts finger tight For NAMUR applications the WS WM Ultraswitch switch shaft features an integral alignment pin This pin must engage the tapped hole in the actuator shaft For non NAMUR applications make sure to properly install a coupler between the WS WM Ultraswitc...

Page 9: ...he clockwise position the bottom switch should only be used to indicate the counter clockwise position Any deviation from these settings may result in erratic indication Solenoids may also be wired through the WS WM Ultraswitch enclosure At least two auxiliary terminals are included as standard Wire the solenoid to auxiliary terminals then connect power leads to the opposite terminal side Be sure ...

Page 10: ...uminum housing Resin housing Aluminum or Resin cover Arrow Indicator Polycarbonate transparent cover Arrow Indicator Polycarbonate transparent cover Dome Indicator Aluminum or Resin cover flat 6 2 Cover and housing options FCD PMENIM0010 02 06 19 ...

Page 11: ...just cam s associated with CW as follows 1 Push or pull cam against spring to disengage it from splines 2 Rotate cam CW breaking contact with switch or moving magnet away from switch 3 Continue rotating cam CW just until switch trips 4 Release cam and re engage it with splines Rotate actuator valve to full counter clockwise CCW position Adjust cam s associated with CCW as described in steps 1 thro...

Page 12: ...perl Fuchs NJ4 12GM40 E N2 Pepperl Fuchs NJ2 12GK N N3 Pepperl Fuchs SJ3 5 S1N N4 Pepperl Fuchs NJ2 12GK SN N5 Pepperl Fuchs NJ4 12GK40 E N6 Pepperl Fuchs NJ4 12GK40 E1 N7 Pepperl Fuchs NBB2 V3 E0 N8 Solid State Proximity Pepperl Fuchs NJ2 V3 N NAMUR Sensor Output 5 25 VDC Supply N9 Solid State Proximity Pepperl Fuchs NBB3 V3 Z4 NPN Sourcing 100 mA max Current 5 60 VDC NA Pepperl Fuchs NBN4 12GM40...

Page 13: ...B2 V3 E3 NY Solid State Proximity Pepperl Fuchs NJ4 12GK SN NAMUR Sensor Output 5 25 VDC Supply P4 SPST Proximity Aleph PS 6132 0 35A at 140 VAC 25A at 200VDC 50 W Max P5 SPDT Proximity Hamlin 59135 030 0 25A at 120 VAC 0 25A at 28 VDC 3 W Max PE SPDT Sabre Pxy Flowserve XA0199 1A at 120 VAC 1A at 24 VDC PP SPDT Phazer Pxy Flowserve XA0155 3A at 120 VAC 2A at 24 VDC PT SPST BRS Pxy Flowserve XA015...

Page 14: ...14 8 Dimensions WS body enclosure WM body enclosure FCD PMENIM0010 02 06 19 ...

Page 15: ...52 Dome indicator assembly red green 2 D2 SP17 Dome indicator assembly black yellow 3 M800214 Polycarbonate transparent cover with dome indicator red green 4 M800215 Polycarbonate transparent cover with arrow indicator 5 ME1967 Gasket for cover all cover types 1 2 3 4 5 FCD PMENIM0010 02 06 19 ...

Page 16: ...nually improving and upgrading its product design the specifications dimensions and information contained herein are subject to change without notice Should any question arise concerning these provisions the purchaser user should contact Flowserve Corporation at any one of its worldwide operations or offices For more information about Flowserve Corporation contact www flowserve com or call USA 1 8...