314
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Enabling port-based VLANs
9
Syntax: system-max mac <max-flow-MACs>
The <max-flow-MACs> parameter specifies the maximum number of MAC addresses in the MAC
table. For flow-based MACs, the minimum value is 16K and the maximum value is 32K. The
default is 16K.
Use the command show default values to display the default, maximum, and currently configured
values for the MAC address table.
Displaying information about flow-based MACs
The show mac-address command includes information related to flow-based MAC address
learning. The following shows an example show mac output.
PowerConnect# show mac
Total active entries from all ports = 15
MAC-Address Port Type Index
0000.0000.0001 1/1 Dynamic NA
0000.0000.0002 1/1 Dynamic NA
In the above example, since both MAC address entries are flow-based and are located on different
packet processors (hardware index), the Index field displays NA (not applicable).
Syntax: show mac
To display all of the packet processors that have a particular flow-based MAC address, use the
show mac-address vlan command.
PowerConnect#show mac-address vlan 1 0000.0000.0001
Total active entries from all ports = 16
MAC-Address Port Type Index
0000.0000.0001 1/1 Dynamic NA
Present in following devices (at hw index) :-
0 (8196 ) 4 (8196 )
In the above example, the MAC address 0000.0000.0001 is programmed in packet processors 0
and 4, and the hardware index is 8196.
Syntax: show mac-address vlan <vlan-num> <mac address>
Clearing flow-based MAC address entries
To remove dynamically-learned MAC addresses from the MAC table, use the CLI command clear
mac. This command clears all dynamically-learned MACs from the hardware and software MAC
tables.
Enabling port-based VLANs
When using the CLI, port and protocol-based VLANs are created by entering one of the following
commands at the global CONFIG level of the CLI.
To create a port-based VLAN, enter commands such as the following.
PowerConnect(config)#vlan 222 by port
PowerConnect(config)#vlan 222 name Mktg
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...