PowerConnect B-Series FCX Configuration Guide
1393
53-1002266-01
Syslog messages
41
Alert
Management module at slot
<slot-num>
state changed from
<module-state>
to
<module-state>
.
Indicates a state change in a management
module.
The
<slot-num>
indicates the chassis slot
containing the module.
The
<module-state>
can be one of the
following:
•
active
•
standby
•
crashed
•
coming-up
•
unknown
Alert
OSPF LSA Overflow, LSA Type =
<lsa-type>
Indicates an LSA database overflow.
The
<lsa-type>
parameter indicates the
type of LSA that experienced the overflow
condition. The LSA type is one of the
following:
•
1 – Router
•
2 – Network
•
3 – Summary
•
4 – Summary
•
5 – External
Alert
OSPF Memory Overflow
OSPF has run out of memory.
Alert
Power supply
<num>, <location>
, failed
A power supply has failed.
The
<num>
is the power supply number.
The
<location>
describes where the failed
power supply is in the chassis.
Alert
System: Module in slot
<slot-num>
encountered PCI config read error: Bus
<PCI-bus-number>
, Dev
<PCI-device-number>
, Reg Offset
<PCI-config-register-offset>
.
The module encountered a hardware
configuration read error.
Alert
System: Module in slot
<slot-num>
encountered PCI config write error: Bus
<PCI-bus-number>
, Dev
<PCI-device-number>
, Reg Offset
<PCI-config-register-offset>
.
The module encountered a hardware
configuration write error.
Alert
System: Module in slot
<slot-num>
encountered PCI memory read error: Mem
Addr
<memory-address>
The module encountered a hardware
memory read error.
The
<memory-address>
is in hexadecimal
format.
Alert
System: Module in slot
<slot-num>
encountered PCI memory write error: Mem
Addr
<memory-address>
.
The module encountered a hardware
memory write error.
The
<memory-address>
is in hexadecimal
format.
Alert
System: Module in slot
<slot-num>
encountered unrecoverable PCI bridge
validation failure. Module will be deleted.
The module encountered an unrecoverable
(hardware) bridge validation failure. The
module will be disabled or powered down.
TABLE 239
Syslog messages (Continued)
Message level
Message
Explanation
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...