104
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Building an IronStack
5
1 S FCX648 active 00e0.52ab.cd00 128 local Ready
2 D FCX624 standby 0012.f2d5.2100 60 remote Ready
3 D FCX624 member 0012.f239.2d40 0 remote Ready
active standby
+---+ +---+ +---+
-2/1| 1 |3/1--2/1| 2 |3/1--2/2| 3 |2/1-
+---+ +---+ +---+
Current stack management MAC is 00e0.52ab.cd00
NOTE
For field descriptions for the show stack command, refer to
“Displaying stack information”
on
page 135.
NOTE
In this output, D indicates a dynamic configuration. After you perform a write memory, this display
will change to S, for static configuration.
6. The Active Controller automatically checks all prospective stack members to see if they are
password protected. If a unit is password protected, you will be asked to enter the password
before you can add the unit. If you do not know the password, take one of the following actions:
•
Discontinue secure-setup by entering ^C
•
Obtain the device password from the administrator
•
Continue secure-setup for your stack. The password-protected device and all devices
connected behind it will not be included in the setup process.
In the following example, the second unit is password protected, so you are asked for the
password.
PowerConnect# stack secure-setup
PowerConnect# Discovering the stack topology...
Verifying password for the password protected units...
Found UPSTREAM units
Hop(s) Type Mac Address
1 2 FCX648 001b.ed5e.c480
2 3 FCX648 00e0.5205.0000
Enter password for FCX648 located at 2 hop(s): ****
Enter the number of the desired UPSTREAM units (1-2)[1]: 2
Selected Topology:
Active Id Type Mac Address
1 FCX624 00e0.5201.4000
Selected UPSTREAM units
Hop(s) Id Type Mac Address
1 2 FCX648 001b.ed5e.c480
2 3 FCX648 00e0.5205.0000
Do you accept the unit id's (y/n)?: y
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...