PowerConnect B-Series FCX Configuration Guide
1129
53-1002266-01
Displaying VRRP and VRRPE information
31
Syntax: show ip vrrp-extended brief | ethernet [
<slotnum>
/]
<portnum>
| ve
<num>
| stat
The brief parameter displays summary information. Refer to
“Displaying summary information”
on
page 1122.
If you specify a port, the
<slotnum>
parameter is required on chassis devices.
The
<portnum>
parameter specifies an Ethernet port. If you use this parameter, the command
displays detailed VRRP or VRRPE information only for the specified port. Refer to
“Displaying
detailed information”
on page 1123.
The ve
<num>
parameter specifies a virtual interface. If you use this parameter, the command
displays detailed VRRP or VRRPE information only for the specified virtual interface. Refer to
“Displaying detailed information”
on page 1123.
The statistic parameter displays statistics. This parameter is required for displaying the statistics.
This display shows the following information.
TABLE 198
CLI display of VRRP or VRRPE statistics
This field...
Displays...
Interface statistics
Interface
The interface on which VRRP or VRRPE is configured. If VRRP or VRRPE is
configured on more than one interface, the display lists the statistics
separately for each interface.
rxed vrrp header error count
The number of VRRP or VRRPE packets received by the interface that had a
header error.
rxed vrrp auth error count
The number of VRRP or VRRPE packets received by the interface that had an
authentication error.
rxed vrrp auth passwd mismatch
error count
The number of VRRP or VRRPE packets received by the interface that had a
password value that does not match the password used by the interface for
authentication.
rxed vrrp vrid not found error
count
The number of VRRP or VRRPE packets received by the interface that
contained a VRID that is not configured on this interface.
VRID statistics
rxed arp packet drop count
The number of ARP packets addressed to the VRID that were dropped.
rxed ip packet drop count
The number of IP packets addressed to the VRID that were dropped.
rxed vrrp port mismatch count
The number of packets received that did not match the configuration for the
receiving interface.
rxed vrrp ip address mismatch
count
The number of packets received that did not match the configured IP
addresses.
rxed vrrp hello interval mismatch
count
The number of packets received that did not match the configured Hello
interval.
rxed vrrp priority zero from
master count
The current Master has resigned.
rxed vrrp higher priority count
The number of VRRP or VRRPE packets received by the interface that had a
higher backup priority for the VRID than this Layer 3 Switch backup priority for
the VRID.
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...