110
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Building an IronStack
5
NOTE
If you are adding PowerConnect B-Series FCX-E or PowerConnect B-Series FCX-I devices to a stack
containing PowerConnect B-Series FCX-S devices, you must reconfigure the stacking ports on the
PowerConnect B-Series FCX-S devices to be the 10 Gbps ports on the front panel. You can then
connect all of the devices in a stack using front panel ports.
Changing PowerConnect B-Series FCX-S and CX4 ports from 16 Gbps to 10 Gbps
You can configure the 16 Gbps PowerConnect B-Series FCX4 ports to operate as 10 Gbps ports
using the speed-duplex command, as shown in the following example.
Syntax: speed-duplex [10-full | 10-half | 100-full | 100-half | 1000-full-master | 1000-full-slave
|10g-full | auto]
•
10-full - 10M, full duplex
•
10-half - 10M, half duplex
•
100-full - 100M, full duplex
•
100-half - 100M, half duplex
•
1000-full-master - 1G, full duplex, master
•
1000-full-slave - 1G, full duplex, slave
•
10g-full - 10G, full duplex
•
auto - Autonegotiation
NOTE
Both ends of a link must be configured for 10 Gbps for the link to operate as 10 Gbps. If you want
the link to operate as a 16 Gbps link, both ends of the link must be configured for 16 Gbps.
PowerConnect(config-if-e10000-cx4-1/2/1)#
speed-duplex 10g-full
PowerConnect(config-if-e10000-cx4-1/2/1)# end
PowerConnect# show int br | in Up
1/1/4 Up Forward Full 1G None No 1 0 001b.f288.0003
1/2/1 Up Forward Full 10G None No 1 0 001b.f288.0019
1/3/1 Up Forward Full 10G None No N/A 0 001b.f288.001b
3/3/1 Up Forward Full 10G None No N/A 0 0024.3814.9df3
mgmt1 Up None Full 1G None No 1 0 001b.f288.0018
PowerConnect# show interface e 1/2/1
16GigabitEthernet1/2/1 is up, line protocol is up
Hardware is 16GigabitEthernet, address is 001b.f288.0019 (bia 001b.f288.0019)
Interface type is 16Gig CX4
Configured speed 10Gbit, actual 10Gbit, configured duplex fdx, actual fdx
Member of L2 VLAN ID 1, port is untagged, port state is FORWARDING
BPDU guard is Disabled, ROOT protect is Disabled
Link Error Dampening is Disabled
STP configured to ON, priority is level0, mac-learning is enabled
Flow Control is enabled
mirror disabled, monitor disabled
Not member of any active trunks
Not member of any configured trunks
No port name
IP MTU 1500 bytes, encapsulation ethernet
300 second input rate: 0 bits/sec, 0 packets/sec, 0.00% utilization
300 second output rate: 0 bits/sec, 0 packets/sec, 0.00% utilization
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts, 0 multicasts, 0 unicasts
0 input errors, 0 CRC, 0 frame, 0 ignored
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...