518
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Displaying GVRP information
14
Syntax: show gvrp vlan all | brief |
<vlan-id>
This display shows the following information.
To display detailed information for a specific VLAN, enter a command such as the following.
TABLE 84
CLI display of summary VLAN information for GVRP
This field...
Displays...
Number of VLANs in the GVRP
Database
The number of VLANs in the GVRP database.
NOTE: This number includes the default VLAN (1), the GVRP base VLAN
(4093), and the single STP VLAN (4094). These VLANs are not
advertised by GVRP but are included in the total count.
Maximum Number of VLANs that
can be present
The maximum number of VLANs that can be configured on the device. This
number includes statically configured VLANs, VLANs learned through GVRP,
and VLANs 1, 4093, and 4094.
To change the maximum number of VLANs the device can have, use the
system-max vlan
<num>
command. Refer to
“Displaying and modifying system
parameter default settings”
on page 321.
VLAN-ID
The VLAN ID.
MODE
The type of VLAN, which can be one of the following:
•
STATIC – The VLAN is statically configured and cannot be removed by
GVRP. This includes VLANs you have configured as well as the default
VLAN (1), base GVRP VLAN (4093), and Single STP VLAN (4094).
•
DYNAMIC – The VLAN was learned through GVRP.
VLAN-INDEX
A number used as an index into the internal database.
PowerConnect#show gvrp vlan brief
Number of VLANs in the GVRP Database: 7
Maximum Number of VLANs that can be present: 4095
[VLAN-ID] [MODE] [VLAN-INDEX]
1 STATIC-DEFAULT 0
7 STATIC 2
11 STATIC 4
1001 DYNAMIC 7
1003 DYNAMIC 8
4093 STATIC-GVRP-BASE-VLAN 6
4094 STATIC-SINGLE-SPAN-VLAN 5
===========================================================================
PowerConnect#show gvrp vlan 1001
VLAN-ID: 1001, VLAN-INDEX: 7, STATIC: NO, DEFAULT: NO, BASE-VLAN: NO
Timer to Delete Entry Running: NO
Legend: [S=Slot]
Forbidden Members: None
Fixed Members: None
Normal(Dynamic) Members: (S2) 1
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...