146
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Managing your IronStack
5
Syntax: show interfaces stack-ports
Table 35
describes the fields displayed by the show interfaces stack-ports command.
Displaying stacking port statistics
The show statistics stack-ports command displays information about all stacking ports in an
IronStack topology.
PowerConnect# show statistics stack-ports
Port In Packets Out Packets In Errors Out Errors
1/2/1 22223 4528 0 0
1/2/2 35506 3844 0 0
2/2/1 3161 34173 0 0
2/2/2 24721 3676 0 0
3/2/1 3048 23881 0 0
3/2/2 13540 2857 0 0
4/2/1 2862 13537 0 0
4/2/2 3626 3184 0 0
5/2/1 3183 3621 0 0
5/2/2 3265 13508 0 0
6/2/1 14020 3655 0 0
6/3/1 3652 17705 0 0
7/2/1 17705 3658 0 0
7/3/1 4047 21802 0 0
TOTAL 154559 153629 0 0
TABLE 35
Field descriptions for the show interfaces stack-ports command
This field
Indicates...
Port
The stack identification number for this unit.
Link
Identifies the configuration for modules on this unit.
State
Indicates that a priority has been assigned to this stack unit
Dupl
Indicates whether the port is configured as half or full duplex
Speed
Indicates the port speed
Trunk
Indicates whether the port is part of a trunk
Tag
Indicates whether the port is tagged or untagged
P
Port priority
MAC
The MAC address of the port
Name
An optional name assigned to the port
PowerConnect# show interfaces stack-ports
Port Link State Dupl Speed Trunk Tag P MAC Name
1/2/1 Up Forward Full 10G-CX4 None No l 0012.f2e4.6e30
1/2/2 Up Forward Full 10G-CX4 None No l 0012.f2e4.6e31
2/2/1 Up Forward Full 10G-CX4 None No l 0012.f2e3.11f0
2/2/2 Up Forward Full 10G-CX4 None No l 0012.f2e3.11f1
3/2/1 Up Forward Full 10G-CX4 None No l 0012.f2db.e530
3/2/2 Up Forward Full 10G-CX4 None No l 0012.f2db.e531
4/2/1 Up Forward Full 10G-CX4 None No l 0012.f2e2.c770
4/2/2 Up Forward Full 10G-CX4 None No l 0012.f2e2.c771
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...