194
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Digital optical monitoring
6
Port 24: Type : 1G M-C
Port 25: Type : 10G XG-SR(XFP)
Vendor: Brocade Communications Inc. Version: 02
Part# : JXPR01SW05306 Serial#: F617604000A3
Port 26: Type : EMPTY
Use the show media slot command to obtain information about the media device installed in a slot.
PowerConnect#show media slot 1
Port 1/1: Type : 1G M-SX(SFP)
Vendor: Brocade Communications, Inc. Version:
Part# : PL-XPL-VC-S13-19 Serial#: 425HC109
Port 1/2: Type : 1G M-SX(SFP)
Vendor: Brocade Communications, Inc. Version:
Part# : PL-XPL-VC-S13-19 Serial#: 411HC0AH
Port 1/3: Type : EMPTY
Port 1/4: Type : 1G M-SX(SFP)
Vendor: Brocade Communications, Inc.
Version: X1
Part# : FTRJ-8519-3 Serial#: H11654K
Port 1/5: Type : EMPTY
Port 1/6: Type : EMPTY
Port 1/7: Type : 100M M-FX-IR(SFP)
Vendor: Brocade Communications, Inc. Version: A
Part# : FTLF1323P1BTR-FD Serial#: UCT000T
Port 1/8: Type : EMPTY
Port 1/9: Type : 100M M-FX-LR(SFP)
Vendor: Brocade Communications, Inc. Version: A
Part# : FTLF1323P1BTL-FD Serial#: UD3085J
Port 1/10: Type : EMPTY
Port 1/11: Type : 100M M-FX-SR(SFP)
Vendor: Brocade Communications, Inc. Version: A
Part# : FTLF1217P2BTL-F1 Serial#: UCQ003J
Port 1/12: Type : EMPTY
Port 1/13: Type : 100M M-FX-IR(SFP)
Vendor: Brocade Communications, Inc. Version: A
Part# : FTLF1323P1BTR-F1 Serial#: PCA2XC5
Use the show media ethernet command to obtain information about the media device installed in a
port.
PowerConnect#show media e 1/17
Port 1/17: Type : 1G M-SX(SFP)
Vendor: Brocade Communications, Inc. Version:
Part# : PL-XPL-VC-S13-19 Serial#: 425HC109
Syntax: show media [slot
<slot-num>
| ethernet [
<slot-num>
/]
<port-num>
]
Viewing optical monitoring information
You can view temperature and power information for qualified XFPs and SFPs installed in a
PowerConnect device.
Use the show optic <
port-number
> command to view information about an XFP or SFP installed in
a particular port. The following shows example output.
PowerConnect#show optic 13
Port Temperature Tx Power Rx Power Tx Bias Current
+----+-----------+----------+------------+-------------------+
13 33.2968 C -005.4075 dBm -007.4328 dBm 6.306 mA
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...