PowerConnect B-Series FCX Configuration Guide
411
53-1002266-01
Dynamic link aggregation
12
•
With LACP trunk configurations, the LACP system id is the MAC address of the Active Controller.
If the LACP system id changes, the entire trunk flaps and an STP re-convergence occurs.
•
Link aggregation can be used to form multi-slot aggregate links on stack units, but the link
aggregation keys must match for the port groups on each stack unit. For example, to configure
an aggregate link containing ports 1/1/1 through 1/1/4, and 3/1/5 through 3/1/8, you must
change the link aggregation key on one or both port groups so that the key is the same for all 8
ports. See the following example.
IronStack LACP trunk group configuration example
To configure a trunk group consisting of two groups of two ports each on an IronStack, enter
commands similar to the following.
PowerConnect(config)#interface ethernet 1/1/1 to 1/1/4
PowerConnect(config-mif-1/1/1-1/1/4)#link-aggregate off
PowerConnect(config-mif-1/1/1-1/1/4)#link-aggregate configure key 10000
PowerConnect(config-mif-1/1/1-1/1/4)#link-aggregate active
PowerConnect(config-mif-1/1/1-1/1/4)#interface ethernet 3/1/5 to 3/1/8
PowerConnect(config-mif-3/1/5-3/1/8)#link-aggregate off
PowerConnect(config-mif-3/1/5-3/1/8)#link-aggregate configure key 10000
PowerConnect(config-mif-3/1/5-3/1/8)#link-aggregate active
This command sequence changes the key for ports 1/1/1-1/1/4 and 3/1/5-3/1/8 to 10000.
Since all ports in an aggregate link must have the same key, this example forms a multi-slot
aggregate link for ports 1/1/1-1/1/4 and
3/1/5-3/1/8.
Examples of valid LACP trunk groups
Dell PowerConnect ports follow the same configuration rules for dynamically created aggregate
links as they do for statically configured trunk groups. Refer to
“Trunk group rules”
on page 395
and
“Trunk group load sharing”
on page 398.
Figure 82
on page 412 shows some examples of valid aggregate links.
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...