PowerConnect B-Series FCX Configuration Guide
851
53-1002266-01
Configuring IP parameters – Layer 3 Switches
26
Displaying DHCP server information
The following DHCP show commands may be entered from any level of the CLI.
Display active lease entries
The show ip dhcp-server binding command displays a specific active lease, or all active leases, as
shown in this example:
PowerConnect# show ip dhcp-server binding
The following output is displayed:
PowerConnect# show ip dhcp-server bind
Bindings from all pools:
IP Address Client-ID/ Lease expiration Type
Hardware address
192.168.1.2 001b.ed5d.a440 0d:0h:29m:31s Automatic
192.168.1.3 0012.f2e1.26c0 0d:0h:29m:38s Automatic
Syntax: show ip dhcp-server binding [<
address
>]
•
<
address
> - Displays entries for this address only
The following table describes this output.
Display address-pool information
This show ip dhcp-server address-pool command displays information about a specific address
pool, or for all address pools.
PowerConnect# show ip dhcp-server address-pools
Output similar to the following is displayed, as shown here.
Showing all address pool(s):
Pool Name: one
Time elapsed since last save: 0d:0h:6m:52s
Total number of active leases: 2
Address Pool State: active
IP Address Exclusions: 192.168.1.45
IP Address Exclusions: 192.168.1.99 192.168.1.103
Pool Configured Options:
bootfile: example.bin
dhcp-default-router: 192.168.1.1
dns-server: 192.168.1.100
domain-name: example.com
lease: 0 0 30
TABLE 154
CLI display of show ip dhcp-server binding command
This field...
Displays...
IP address
The IP addresses currently in the binding database
Client ID/Hardware address
The hardware address for the client
Lease expiration
The time when this lease will expire
Type
The type of lease
Summary of Contents for PowerConnect B-FCXs
Page 1: ...53 1002266 01 18 March 2011 PowerConnect B Series FCX Configuration Guide ...
Page 248: ...206 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IPv6 management commands 7 ...
Page 374: ...332 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Jumbo frame support 9 ...
Page 568: ...526 PowerConnect B Series FCX Configuration Guide 53 1002266 01 CLI examples 14 ...
Page 588: ...546 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Sample application 15 ...
Page 684: ...642 PowerConnect B Series FCX Configuration Guide 53 1002266 01 VLAN based mirroring 20 ...
Page 724: ...682 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Reading CDP packets 23 ...
Page 930: ...888 PowerConnect B Series FCX Configuration Guide 53 1002266 01 26 ...
Page 948: ...906 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Configuring MLD snooping 27 ...
Page 1348: ...1306 PowerConnect B Series FCX Configuration Guide 53 1002266 01 Example configurations 36 ...
Page 1406: ...1364 PowerConnect B Series FCX Configuration Guide 53 1002266 01 IP source guard 39 ...