4
|
Components
Service manual
202
EBLA04~08E + EDLA04~08E
Daikin Altherma 3 M
ESIE22-09 – 2022.05
Is the problem solved?
Action
Yes
No further actions required.
No
fan motor and continue with the next
procedure.
4.16 Plate work
4.16.1 To remove the discharge grille
Prerequisite:
Stop the unit operation via the user interface.
1
Turn OFF the respective circuit breaker.
DANGER: RISK OF ELECTROCUTION
Wait for at least 10 minutes after the circuit breaker has been turned OFF, to be sure
the rectifier voltage is below 10 V DC before proceeding.
2
Loosen and remove the screws that fix the discharge grille.
a
a
a
a
a
a
a
Screw
3
Remove the discharge grille.
4.16.2 To open the outdoor unit
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING/SCALDING
draft – 31/05/2022 15:53