![background image](http://html1.mh-extra.com/html/daikin/ebla04e-v-series/ebla04e-v-series_service-manual_4704429203.webp)
4
|
Components
Service manual
203
EBLA04~08E + EDLA04~08E
Daikin Altherma 3 M
ESIE22-09 – 2022.05
1
1
1
5×
2
4.16.3 To remove the top plate
INFORMATION
This procedure is just an example and may differ on some details for your actual unit.
Prerequisite:
Stop the unit operation via the user interface.
1
Turn OFF the respective circuit breaker.
DANGER: RISK OF ELECTROCUTION
Wait for at least 10 minutes after the circuit breaker has been turned OFF, to be sure
the rectifier voltage is below 10 V DC before proceeding.
2
Loosen and remove the screws that fix the top plate.
a
b
a
a
a
a a
a
a a
a
Screw
b
Top plate
3
Remove the top plate.
4.16.4 To remove the front plate
Prerequisite:
Open the outdoor unit, see
Prerequisite:
Remove the top plate and the discharge grille, see
1
Remove the retainers from the hinges of the hydro switch box.