4
|
Components
Service manual
214
EBLA04~08E + EDLA04~08E
Daikin Altherma 3 M
ESIE22-09 – 2022.05
V (DC)
Detected pressure MPa
2.7
3.05
2.8
3.18
2.9
3.32
3.0
3.46
3.1
3.60
3.2
3.74
3.3
3.87
3.4
4.01
3.5
4.15
3.6
4.29
INFORMATION
The refrigerant pressure sensor connector MUST be plugged into the appropriate
PCB.
4
Measure the voltage on connector X60A: pins 1–3 (= refrigerant pressure
sensor output signal) on the hydro PCB.
5
Check that the measured voltage is in line with the expected voltage through
the read refrigerant pressure.
INFORMATION
Make sure that the wiring between the sensor connector and the connector on the
PCB is properly connected and NOT damaged (check continuity), see
281].
The measured voltage is inside the
expected range?
Action
Yes
Refrigerant pressure sensor is OK.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
No
Continue with the next step.
6
Unplug the refrigerant pressure sensor connector X6Y and measure the
voltage between the pins 3–4 (pressure sensor power supply).
If measured voltage…
Then
Is +5 V DC
Replace the refrigerant pressure sensor,
see
Is not +5 V DC
Continue with the next step in the
procedure
7
Unplug the connector X60A and measure the voltage (power supply) between
pins 3–4 on the hydro PCB.
Result:
The measured voltage MUST be +5 V DC.
draft – 31/05/2022 15:53