5/14
Breadcrumb
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
Installer settings
└─
Configuration wizard
└─
System
9.1.3.2
[E-03]
R/O (*3)
R/W (*4)
0: No heater (*4)
1: External heater
2: 3V (*3)
9.1.3.3
[E-05]
[E-06]
[E-07]
R/W
E-05=0
No DHW
E-07 = 0
EKHWS/E, small volume
E-07 = 3
EKHWS/E, big volume
E-07 = 5
EKHWP/HYC
E-07 = 7
3rd party, small coil
E-07 = 8
3rd party, big coil
9.1.3.4
[4-06]
R/W
0: Manual
1: Automatic
2: Auto SH reduced/ DHW ON
3: Auto SH reduced/ DHW OFF
4: Auto SH normal/ DHW OFF
9.1.3.5
[7-02]
R/W
0: Single zone
1: Dual zone
9.1.3.6
[E-0D]
R/W
0: No
1: Yes
9.1.3.7
[6-02]
R/W
0~10kW, step: 0,2kW
3kW
9.1.3.8
[C-02]
R/W
0: NO
1: Yes
9.2.4
[D-07]
R/W
0: No
1: Yes (DHW)
└─
Backup heater
9.1.4.1
[5-0D]
R/O(*3)
R/W(*4)
0: 230V, 1~ (*3)
1: 230V, 3~
2: 400V, 3~
9.1.4.2
[4-0A]
R/W
0: 1
1: 1/1+2
2: 1/2
3: 1/2 + 1/1+2 in emergency
9.1.4.3
[6-03]
R/W
0~10kW, step: 0,2kW
0kW (*4)
3kW (*3)
9.1.4.4
[6-04]
R/W (*4)
R/O (*3)
0~10kW, step: 0,2kW
0kW (*3)
└─
Main zone
9.1.5.1
[2-0C]
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
9.1.5.2
[C-07]
R/W
0: Leaving water
1: External room thermostat
2: Room thermostat
9.1.5.3
R/W
0: Fixed
1: WD heating, fixed cooling
2: Weather dependent
9.1.5.4
R/W
0: No
1: Yes
9.1.5.5
R/W
0: 2-points
1: Slope-Offset
9.1.6
[1-00]
R/W
-40~5°C, step: 1°C
-10°C
9.1.6
[1-01]
R/W
10~25°C, step: 1°C
15°C
9.1.6
[1-02]
R/W
[9-01]~[9-00], step: 1°C
[2-0C]=0
35°C
[2-0C]=1
45°C
[2-0C]=2
60°C
9.1.6
[1-03]
R/W
[9-01]~min(45, [9-00])°C , step: 1°C
[2-0C]=0
25°C
[2-0C]=1
35°C
[2-0C]=2
40°C
9.1.7
[1-06]
R/W
10~25°C, step: 1°C
20°C
9.1.7
[1-07]
R/W
25~43°C, step: 1°C
35°C
9.1.7
[1-08]
R/W
[9-03]~[9-02]°C, step: 1°C
[2-0C]=0
22°C
[2-0C]=1
15°C
[2-0C]=2
22°C
9.1.7
[1-09]
R/W
[9-03]~[9-02]°C, step: 1°C
[2-0C]=0
18°C
[2-0C]=1
7°C
[2-0C]=2
18°C
└─
Additional zone
BUH type
Domestic hot water
Emergency
Number of zones
Glycol Filled system
BSH capacity
Voltage
Configuration
Capacity step 1
Additional capacity step 2
Bivalent
Solar
Emitter type
Control
Setpoint mode
Schedule
WD curve type
Low ambient temp. for LWT main zone heating WD curve.
High ambient temp. for LWT main zone heating WD curve.
Leaving water value for low ambient temp. for LWT main zone
heating WD curve.
Leaving water value for high ambient temp. for LWT main zone
heating WD curve.
Low ambient temp. for LWT main zone cooling WD curve.
High ambient temp. for LWT main zone cooling WD curve.
Leaving water value for low ambient temp. for LWT main zone
cooling WD curve.
Leaving water value for high ambient temp. for LWT main zone
cooling WD curve.
(*1) EBLA*_(*2) EDLA*_(*3) *23V3_(*4) *2V3
4P685235-1 - 2022.03
Summary of Contents for EBLA04E V Series
Page 322: ...14 14...